7. MAINTENANCE AND PRESERVATION
Correct maintenance is essential to maintain the o-
riginal efficency and safety of the machine over
time.
WARNING!
rations:
– remove the spark plug cap.
– Wait until the engine is sufficiently cold.
– Use protective gloves when handling the
blades.
– Keep the blade protection devices on, ex-
cept when intervening directly on the blade.
– Never dispose of oils, fuel or other polluting
materials in unauthorised places
CLEANING THE ENGINE AND THE SILENCER
To reduce fire risks, periodically clean the cylinder
flaps with compressed air and clear the silencer
area from branches, leaves or other debris.
CLEANING THE AIR FILTER
IMPORTANT
sential to guarantee the efficiency and duration of
the machine.
It must be cleaned after every 15 working hours.
To clean the filter (Fig. 8):
– Press the button (1), turn the cover (2) over and
remove the filter element (3).
– Wash the filter element (3) with soap and water.
Do not use petrol or other solvents.
– Leave the filter to dry in the open air.
– Refit the filter element (3) and close the cover (2)
pushing until it clicks into place.
FUEL FILTER
Inside the fuel tank there is a filter which prevents
impurities from entering the engine.
The filter should be replaced once a year by your
Retailer.
During maintenance ope-
Cleaning the air filter is es-
MAINTENANCE AND PRESERVATION
CHECKING THE SPARK PLUG
Periodically, remove and clean the spark plug from
any eventual deposits using a metal brush.
Check and reset the correct distance between the
electrodes (Fig. 9).
Replace the spark plug and fasten it firmly using the
supplied key.
The spark plug must be replaced with one with the
same characteristics in the cases where the elec-
trodes have burnt or the insulation has worn out,
and in any case every 50 working hours.
TUNING THE CARBURETTOR
The carburettor is tuned by the manufacturer to
achieve maximum performance in all situations of
use, with a minimum emission of toxic gas in com-
pliance with current specifications.
In the case of poor performance, first check that the
blades are not partially blocked or deformed, on the
contrary ask your Retailer to check the carburettor
and the engine.
• Tuning minimum speed
WARNING!
not move when the engine is running idle. If
the cutting device moves when the engine is
running idle, contact your dealer to correctly
regulate the engine.
LUBRICATING THE REDUCTION GEAR
(Fig. 10)
Every 20 working hours, top up the level with spe-
cial molybdenum bisulphur lubrication, injecting it
into the lubricator (1).
BLADE CLEANING AND CHECK
WARNING!
the blades are not bent or deformed and that
the screws are adequately tightened.
Adjustment of the distance between blades is not
necessary, as this is predetermined by the ma-
nufacturer.
The cutting device must
Periodically check that
Tabla de contenido