5.3.5 INSTALLATION PARAMETERS
NOTE
Press STOP before modifying the parameters.
Key sequence to access the installation menu Last button pressed for 10 seconds.
During the modification of the
parameters, the symbol
display lights up
Use the MODE key to change various
parameters
DESCR.
MENU
DISPLAY
TIP O
SCA
INSTALLATION
PARAMETERS
INF F
SUP F
ANP F
SUP S
INF S
OFF P
SPE T
With the buttons it is possible to
on the
modify the values
PARAMETER
NAME
Identifies whether the pump is part of a unit or whether
it is a single pump, possible values:
Pump type
This parameter indicates the mode used to change
pumps when the pump is part of a unit (PRI, SEC). The
possible values are:
Type of exchange
Minimum frequency
Parameter defining minimum motor rotation frequency.
Maximum frequency
Parameter defining maximum motor rotation frequency.
Parameter defining the speed with which the motor
Reactivity factor
responds to changes in pressure. The lower the setting
the faster the motor' s response.
Parameter defining the sensor at the bottom of the
Bottom scale sensor
scale.(in bar[PWE1]).
Zero sensor
Minimum value read by the sensor (zero).
Offset sensor
Use to enter an offset value for the pressure sensor.
Interval of time during which pressure must remain
stable (+/- 0.1 Bar) with a rotation lower than the average
Switching off time
switching off frequency + 10 to trigger the motor shut-
down cycle (seconds).
DESCRIPTION
SING: single pump
PRI: primary or master pump for a unit
SEC: secondary or slave pump for a unit
CH01: Indicates that the first pump to come on at the
next request for water will be the one which started-
up second or which did not start-up during the last
cycle. The second pump can support the first in this
mode (BOOSTER setting).
CH02: Indicates that the first pump to come on at
the next request for water will be the one which did
not start up during the last cycle. The second pump
cannot support the first in this mode.
CH03: Indicates that the first pump to come on at the
next request for water will be the one which has run
for the least amount of time (see functioning hours
parameter). The second pump can support the first in
this mode (BOOSTER setting).
CH04: Indicates that the first pump to come on at the
next request for water will be the one which has run
for the least amount of time (see functioning hours
parameter). The second pump cannot support the
first in this mode.
CH05: In this setting, the first pump to start-up is
the one entered as the primary pump in the "type of
pump" parameter. The second pump can support the
first in this mode; however, the cyclical function is
not available.
To memorize the values press the
button "SET". The symbol
The words "REC" will appear on the
screen for a few seconds to show that
the data has been saved
DEF
MIN
SING
N.A.
CH01
CH01
30
20
50
40
15
1
10
2
0,6
0
0
0
10
3
EN
.
MAX
N.A.
CH05
40
60
50
30
1
10,0
50
35