Maintenance Intervals - Dräger X-plore 5500 Instrucciones De Uso

Ocultar thumbs Ver también para X-plore 5500:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
Special Maintenance
Replacing the lens
Masks with metal lens frame: Unscrew the screws, steadying the
hexagon nuts.
Masks with plastic lens frame: Remove the screws. Prise lens frame
apart at the connecting points using a screwdriver, then pull it off to
the top and bottom
If required, remove connector clamp as well as sliding ring and
supporting plate.
Detach the old lens from its rubber frame.
Insert the new lens first in the upper and then in the lower part of the
rubber frame.
Centre marks on lens must line up with seam in faceblank.
Pull the rubber frame over the edge of the lens on the right and left.
Moisten the outside of the rubber frame and the inside of the lens
frame with soap solution.
Press first the upper clamping frame and then the lower clamping
frame into place.
Fit the sliding ring and new connector clamp, if required. Hook in the
hook in such a way that the connector clamp sits as tight as
possible.
If required, slide the support plate between the connector clamp
and the sliding ring, clamp to the bottom lens frame and align.
Masks with metal lens frame: Screw the screws into the hexagonal
nuts and tighten until the gap between the tightening cams is 3 to
0.5 mm.
Masks with plastic lens frame: Insert screws and tighten.
Replacing the valve discs at the control valves of the
nose cup
Pull out the old valve discs towards the inside.
Insert the studs of the new discs into the hole from the inside, and
pull them towards the lens until the undercut of the stud is visible.
The valve discs should make even contact with the inside surface.
Replacing the screw ring with integrated speech
diaphragm
Pull the inner mask out of the
groove of the screw ring with
integrated speech diaphragm.
Unscrew the screw ring with
integrated speech diaphragm
using pin wrench R 26 817.
Remove the O-ring from the
mask connection using seal
extractor R 21 402.
Examine the O-ring and
replace if necessary.
Moisten the new O-ring with soapy water and insert it.
Screw in the screw ring with integrated speech diaphragm and
tighten it into place with pin wrench R 26 817.
NOTICE
Ensure that the edge of the inner mask is fully inserted in the
groove of the screw ring with integrated speech diaphragm and that
it encloses the screw ring and speech diaphragm completely. The
centre marks on the mask connector and inner mask must be lined
up.
Replacing the exhalation valve disc
Remove protective cap from mask connector.
Pull valve disc out.
Valve disc and seat must be clean and undamaged, otherwise
clean or replace.
Moisten valve disc with water and insert.
Replace protective cap and ensure that it engages.
Replacing the Inhalation Valve Disc
Pull the inhalation valve out by its tab.
Remove old valve disc, attach new valve disc.
Press the inhalation valve into the mask connector until it makes
contact all around. The valve disc must not be squeezed, the disc
points inwards, the ridges point to the outside.
Storage
Loosen the straps as far as they will go.
Wipe lens with an antistatic cloth.
Pack full-face mask in its bag or mask box.
Store undistorted, dry and dust-free.
o
Storage temperature: -15
C to 25
Keep out of direct sunlight and heat.
Observe ISO 2230 "Rubber Products - Guidelines for Storage" and
national regulations for storage, maintenance and cleaning of rubber
products.

Maintenance intervals

The following details are recommendations given in the BGR 190
regulations which apply to Germany. Observe the national
regulations.
Work to be carried out
Inspection by wearer of device
Cleaning and Disinfection
Visual inspection, function and
leak tests
Replacing the exhalation valve
disc
Replacing the speech diaphragm
Replacing the O-ring of the
speech diaphragm
1) Full-face masks in airtight packaging, otherwise every six months.
2) Full-face masks in airtight packaging every 2 years.
Order list
Name and Description
Dräger X-plore 5500
Dräger X-plore 5500 L
Mask spectacle frame
(spectacle frame and retai-
ner)
Mabox mask box (large)
Mabox II mask box (small)
Wikov V mask box
Lens cover
(set of 25)
DAISYquick
(cleaning cloth, set of 10)
"klar-pilot" gel
(anti-misting gel for lens)
®
Sekusept
Cleaner
®
Incidin
Rapid (6 L)
other packaging units
Dräger Testor 2100
o
C.
Maximum intervals
X
1)
X
X
2)
X
X
X
X
X
Part no.
R 55 270
R 56 655
R 51 548
R 53 680
R 54 610
R 51 019
R 25 355
R 54 134
R 52 560
79 04 071
R 61 880
upon request
R 53 400
7
Tabla de contenido
loading

Tabla de contenido