Maintenance; Recommended Inspection And Maintenance Intervals; Cleaning And Disinfecting - Dräger FPS 7000 Instrucciones De Uso

Ocultar thumbs Ver también para FPS 7000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
1. Pull both mask/helmet adapters forward slightly.
Mask/helmet
2. Press and hold the snap fasteners on both mask/
combination
helmet adapters.
with adapter
3. Pull both mask/helmet adapters evenly to the rear,
H62 (Q-fix)
then flip them away from the helmet.
4. Take off the facepiece.
4

Maintenance

4.1
Recommended inspection and maintenance
intervals
The following information is taken from BGR 190, one of the Regula-
tions of the Employer's Liability Insurance Association in Germany.
Observe national regulations.
Type of work to be performed
Check by equipment wearer
Clean and disinfect
Visual inspection, function and leak
test
Replace exhalation valve disc
Replace speech diaphragm
Replace O-ring of the speech dia-
phragm
1)
for airtight packed full face masks, otherwise every 6 months
2)
for airtight packed full face masks every 2 years
Dräger FPS 7000
4.2
Clean and disinfect the facepiece after every use.
!
!
X
1)
X
X
2)
X
X
X
X
X
X
(Certified by Dekra Exam)

Cleaning and disinfecting

WARNING
The mask body must be cleaned sufficiently thoroughly that
no residues from skin care products remain on it.
Otherwise the elasticity in the sealing area can be lost and
the facepiece will no longer sit correctly.
CAUTION
Never use any solvents (e.g. acetone, alcohol) or scouring
agents to clean and disinfect the facepiece. Only use the
methods described and the cleaning agents and disinfectants
listed below. Agents, doses and exposure times that deviate
from the specifications can cause damage to the facepiece.
Undiluted agents that come into direct contact with eyes or
skin are hazardous to health. Therefore always wear protec-
tive goggles and protective gloves when working with such
agents.
Do not use a cloth to clean or dry the inside of facepieces with
visors that are marked "PCaf", as the coating can be dam-
aged as a result. After drying, facepieces should be aired un-
packed for at least one day under standard climatic conditions
according to DIN EN ISO 291, so that the coating can regen-
erate and the optimum working life is achieved.
Maintenance
27