Cleaning and disinfecting procedure
●
Remove any accessories and the mouthpiece from the facepiece
and clean them separately.
●
If a Dräger MS-COM is fitted, put the protective cap on the adapter
for the Dräger MS-COM to avoid injuries.
●
Position the wiper in the middle of the visor.
●
If the facepiece has a drinking valve, the valve must be cleaned
as described in "Cleaning and disinfecting the drinking valve".
●
Prepare a cleaning solution consisting of water and a cleaning
agent.
●
Clean all parts using a soft cloth with cleaning solution.
●
Thoroughly rinse all parts under running water.
●
Prepare a disinfecting solution consisting of water and a
disinfecting agent.
●
Place all parts that need to be disinfected into the disinfectant
bath.
●
Thoroughly rinse all parts under running water.
●
Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
●
Mount the mouthpiece of the drinking valve and the accessories if
necessary.
Use Instructions for NIOSH-approved full facepieces
Alternative cleaning and disinfecting procedure
●
Remove any accessories and the mouthpiece from the facepiece
and clean them separately.
●
If a Dräger MS-COM is fitted, put the protective cap on the adapter
for the Dräger MS-COM to avoid injuries.
●
Position the wiper in the middle of the visor.
●
If the facepiece has a drinking valve, the valve must be cleaned
as described in "Cleaning and disinfecting the drinking valve".
●
Prepare a solution containing water and a combined cleaning and
disinfecting agent.
●
Immerse the facepiece in the solution. Make sure that all parts are
wetted.
●
Thoroughly rinse all parts under running water.
●
Dry all parts in the air or in a drying cabinet (max. temperature:
140 °F/60 °C). Do not expose to direct sunlight. Do not shake the
facepiece in order to remove water.
●
Mount the mouthpiece of the drinking valve and the accessories if
necessary.
137