After use
Uncouple the closed-circuit breathing apparatus: press the button
and at the same time pull the plug-in coupling out of the connector.
To prevent damage, do not pull the connector.
Full face
Remove the helmet if necessary.
mask
Push the adjuster buckles of the neck straps
forward with your thumb and loosen the straps
(Figure E).
Pull the Dräger FPS 7000 RP away from your face
over your head.
Mask/
Open the chin strap of the helmet.
helmet
Pull both mask/helmet adapters evenly to the rear,
combination
then flip them away from the helmet.
with S-fix
Remove the Dräger FPS 7000 RP.
adapter
Remove the helmet.
Mask/
Open the chin strap of the helmet.
helmet
Pull both mask/helmet adapters slightly forward
combination
and press the press studs to unlock.
with Q-fix
Pull both mask/helmet adapters evenly to the rear,
adapter
then flip them away from the helmet.
Remove the Dräger FPS 7000 RP.
Remove the helmet.
CAUTION
(approved by Dekra Exam)
Maintenance
Recommended test and maintenance intervals
The following information complies with DGUV-R 112-190 valid in
Germany. Observe national directives.
Type of work to be performed
Check by the device user
Visual inspection, function and leak test
Cleaning and disinfection
Replace the O-rings on the speech
diaphragm and the wiper shaft
Replace speech diaphragm
Replace the drinking valve
1)
For full face masks in air-tight packaging: every 2 years
2)
For full face masks in air-tight packaging, otherwise every 6 months
X
1)
X
X
2)
X
X
X
X
X
25