SinePower
10
Before initial use
A
NOTICE!
The setting of incorrect values may result in malfunctions and damage.
Note the Technical Data of the connected devices.
I
NOTE
If the power source is lost during the initialisation, you have to reset the
device to its factory settings (chapter "Reset the device to factory set-
tings" on page 20) and then restart the initialisation.
Before you can use the device, you have to initialise it in the DSP-EM.
➤ Switch on the system.
✓ The number "1" appears on the DSP-EM's display.
Without connected battery sensor
➤ Turn the selector button until the number 8 is displayed.
➤ Press the selector button to save the value.
✓ The display shows the service code "S-12".
➤ Turn the selector button to set the battery type:
– 0: Lead acid
– 1: Gel
– 2: AGM
– 3: eStore
– 4: Customer
➤ Press the selector button to save the selected value.
✓ The display shows the service code "S-14".
➤ Turn the selector button to set the maximum charging current in percent (25 %,
50 %, 75 % or 100 % of the rated charging current).
➤ Press the selector button to save the selected value.
✓ The display shows the service code "S-15".
➤ Turn the selector button to set the bulk/absorption voltage (13.5 V to 15.0 V in
0,1 V steps).
➤ Press the selector button to save the selected value.
✓ The display shows the service code "S-16".
EN
Before initial use
19