Electrical Characteristics - Mitsubishi Electric City Multi PLFY-WP-VBM-E Serie Manual De Instalación

Ocultar thumbs Ver también para City Multi PLFY-WP-VBM-E Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Electrical
or

8 Electrical characteristics

Model
PLFY-WP32 BM-E
PLFY-WP4
BM-E
PLFY-WP5
BM-E
9 Ho
to set the
ed up do n air direction (Onl
or
ired re ote controller)
For PLFY-BM, only the particular outlet can be fixed to certain direction with
the procedures below. Once fixed, only the set outlet is fixed every time air
conditioner is turned on. (Other outlets follow UP DOWN air direction setting of
the remote controller.)
E planation o
ord
Address No. of indoor unit is the number given to each air conditioner.
Outlet No. is the number given to each outlet of air conditioner.
(Refer to the right.)
Up Down air direction is the direction (angle) to x.
Manual ane angle
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
Main menu:
Cursor
F1
F2
F3
F4
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Power supply
olts Hz
Range - 1
Max.: 264
22 -24
5 Hz
Min.: 19
1 Select Maintenance from the Main
menu, and press the [SELECT]
button.
2 Select Manual vane angle with the
[F1] or [F2] button, and press the
[SELECT] button.
3 Select the M-NET address for the
units to whose vanes are to be xed,
with the [F2] or [F3] button, and press
the [SELECT] button.
Press the [F4] button to con rm the
unit.
The vane of only the target indoor
unit is pointing downward.
Symbols: MCA: Max. Circuit Amps ( 1.25×FLA)
IFM: Indoor Fan Motor
MCA (A)
Output (kW)
.44
.44
.57
Horizontal air ow
Remote controller setting
The air ow direction of this outlet
is controlled by the air ow direc-
tion setting of remote controller.
Outlet No.3
Outlet No.2
Note: " " indicates all outlets.
Con r ation procedure
Manual vane angle
M-NET address
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
The air conditioner with the
vane pointing downward is
the target air conditioner.
Input display:
F1
F2
F3
F4
Manual vane angle
There is no response from
the target device.
Confirm the state of the air
conditioner.
Input display:
F1
F2
F3
F4
FLA: Full Load Amps
Output: Fan motor rated output
IFM
FLA (A)
. 5
.35
. 5
.35
. 5
.45
Downward
Fixed setting
The air ow direction of this
outlet is xed in particular
direction.
* When it is cold because of direct air ow,
the air ow direction can be xed horizon-
tally to avoid direct air ow.
Outlet No.4
MITSUBISHI
ELECTRIC
label
Outlet No.1
1 Select the M-NET address for the
units to whose vanes are to be xed,
with the [F2] or [F3]
button.
Press the [F4] button to con rm
the unit.
2 After pressing the [F4] button, wait
approximately 15 seconds, and
then check the current state of the
air conditioner.
The vane is pointing downward.
This air conditioner is displayed
on the remote controller.
All outlets are closed.
the [RETURN] button and continue
the operation from the beginning.
The messages shown to the left
are displayed.
The target device
does not exist at this refrigerant ad-
dress.
Press the [RETURN] button to
return to the initial screen.
3 Change the M-NET address to
the next number.
Refer to step 1 to change the M-
NET address and continue with the
con rmation.
Press
Tabla de contenido
loading

Tabla de contenido