D-98
Parameter Reference
IO Values
Monitor::Inputs and Outputs
Parameters::Inputs and Outputs::IO Values
These parameters present the Input and Output values in a form suitable for processing by the application and fieldbus.
Parameter Name
No.
Digout Value
0022
Presents all the digital outputs from the drive as a 16-bit word. The bits within the word may be accessed individually, or the entire
word may be accessed as a group.
Bit
Signal Name
0
Digital Output 01
1
Digital Output 02
2
Digital Output 03
3
Digital Output 04
4
Relay 01
5
Relay 02
8
Digital Output 11
9
Digital Output 12
10
Digital Output 13
11
Digital Output 14
14
Relay 11
15
Relay 12
Path
Monitor::Inputs and Outputs
Parameters::Inputs And Outputs::IO
Values
Terminal
Comment
X12.1
Common terminal with digital input 4
X12.2
Common terminal with digital input 5
X12.3
Common terminal with digital input 6
X12.4
Common terminal with digital input 7
X14.1&2
X14.3&4
X20.1
GPIO option
X20.2
GPIO option
X20.3
GPIO option
X20.4
GPIO option
X23.1 & 2
GPIO option
X23.3 & 4
GPIO option
Default
Range
0000
0:Digout 01
1:Digout 02
2:Digout 03
3:Digout 04
4:Relay 01
5:Relay 02
8:Digout 11
9:Digout 12
10:Digout 13
11:Digout 14
14:Relay 11
15:Relay 12
PNO for individual bit access
0023
0024
0025
0026
0027
0028
0031
0032
0033
0034
0037
0038
Units
Writable
ALWAYS
AC30 series Variable Speed Drive