9. Troubleshooting
Fault
Possible cause
The PT 10 can't be
The supply cords are not (or not fully)
switched on.
connected.
The laser beam is not aimed at the
The PT 10 can't find
the laser beam.
crosshairs.
The laser tool is not switched on.
Not a Hilti laser tool.
Large red and
Measuring could not be completed
green LEDs light
correctly.
constantly.
Small red LED
The wrong filter is selected.
(right) lights con-
stantly.
Large red and small
The PT 10 quick check device and/or the
red LED (left) light
laser tool under test was shaken during
constantly.
measuring.
Large red and
Camera error.
green LED light
constantly despite
several measuring
attempts.
10. Disposal
CAUTION
Improper disposal of the equipment may have serious consequences: The burning of plastic components
generates toxic fumes which may present a health hazard. Batteries may explode if damaged or exposed to
very high temperatures, causing poisoning, burns, acid burns or environmental pollution. Careless disposal
may permit unauthorized and improper use of the equipment. This may result in serious personal injury, injury
to third parties and pollution of the environment.
Most of the materials from which Hilti tools or appliances are manufactured can be recycled. The materials must
be correctly separated before they can be recycled. In many countries, Hilti has already made arrangements
for taking back old tools and appliances for recycling. Ask Hilti customer service or your Hilti representative
for further information.
Printed: 07.07.2013 | Doc-Nr: PUB / 5070500 / 000 / 00
Remedy
Check the supply cord and ensure that all
cords are connected correctly.
Aim the laser beam at the crosshairs.
Switch the laser tool on.
Only genuine Hilti laser tools can be
tested.
Repeat the measuring operation.
Check and correct the filter setting.
Repeat the measuring operation.
Remove the PTA 10 optical level and
return it to a Hilti service center for repair.