Hilti laser tool
PR 20
PR 25
The table of Hilti tools will be updated and replaced when new products are introduced.
2.4 Information displayed during operation
Small green LED
Small yellow LED
Large green and red
LEDs
2.5 PT 10 quick check device in cardboard box - items supplied
1 PT 10 quick check device
1 PTA 70 tripod adapter
1 PTA 45 tripod head
1 PTA 40 tripod column
1 Disc or accessory
1 Mains adaptor
1 Operating instructions
1 Manufacturer's certificate
2.6 PT 10 - associated items in separate box
1
PTA 10 optical level with camera
Printed: 07.07.2013 | Doc-Nr: PUB / 5070500 / 000 / 00
Accuracy class
1
2
The green LED doesn't
light.
The green LED doesn't
light.
The green LED lights
constantly.
The green LED blinks.
The yellow LED doesn't
light.
The yellow LED doesn't
light.
Only one yellow LED
lights.
Both LEDs light con-
stantly.
Both yellow LEDs blink.
The green LED lights.
The red LED lights.
Filter setting
I
I
The tool is switched off.
The tool is not connected to the electric supply.
Beam search for the laser beam from the tool under
test is active. After searching in beam search mode
unsuccessfully for 2 minutes, the PT 10 quick check
device reverts automatically to standby mode.
Ready mode.
The laser beam is not aimed at the opening in the
filter unit and therefore not at the camera. Use the
fine adjustment screws to rotate the optical level
until both yellow LEDs light constantly.
The laser beam is not striking the camera. Check
that the Hilti laser tool is switched on.
The laser beam is striking the camera only partially.
Use the fine adjustment screws to rotate the optical
level until both yellow LEDs light constantly.
The laser beam is striking the camera and the tool is
ready to begin measuring.
Information displayed while measuring is in
progress.
Result of test: The laser tool under test is within the
specified accuracy.
Result of test: The laser tool under test is not within
the specified accuracy and must be returned to a
Hilti service center for calibration.
en
13