INSTALLATION

1.
Location:
Install the compressor in a covered, well ventilated area, free from dust gases, toxic gases, humidity or any
other sources of contamination. The presence of contaminants in the air (dust, fibers, etc.) may cause
premature obstruction to the air filter and the air/oil after-cooler (please see chapter on preventive
maintenance, pages 51 and 54, items
contaminate the oil, causing lubricating problems and diminished air quality. For installation in highly
contaminated areas, a heavy duty remote air inlet filter kit can be purchased and installed. (Consult your
SCHULZ Authorized - Technical/Distributor
ambient temperature is 40°C (104°F). Should temperature be higher, exhaust fans or must be provided in
order to bring ambient temperature to its required level. The lower the temperature, the better the
compressor's working conditions. The installation of a hot air duct from the compressor's cooling air outlet
may be installed. Care should be taken to insure that NO AIR FLOW RESTRICTION is created. Connection
to the compressor cabinet must also be accomplished in such a manner as to insure the ease of maintenance
(Consult your
SCHULZ Authorized - Technical/Distributor
ATTENTION
2.
Position and dimension
Place compressor a minimum distance (See Figure 4, page 40 ) from any wall or obstacle to facilitate
adequate air flow and ease of maintenance.
3. Mounting
Remove compressor from pallet and crating and place it on a level concrete floor. It is not necessary to install
anti-vibration devices or to anchor the frame to the floor.
4. Electrical Connection
Before connecting electrical power supply it is recommended that internal electrical connections be checked
for security following shipping. Consult a licensed electrician to evaluate power supply and install
appropriate electrical connections for your air compressor. Your compressor must be installed in accordance
with federal state and local electrical codes. Wiring must be sized appropriately to accommodate in-rush
current and distance to power supply (See Table 2, page 41). A fused disconnect (with timed delay
fuses)should be installed near the compressor (see Table 1 - Technical Data, page 37).
ATTENTION
The electrical power supply should not have a voltage variation greater than ± 10%.
The voltage drop caused by the motor's start up should not exceed 10%.
The frame of the compressor should be grounded appropriately.
The Compressor's Electrical Panel has a terminal block (X2) for the incorporation of a remote start switch.
The motor starter configuration includes a thermal overload relay for the protection of the compressor.
Figure 6, page 42 shows an guidelines and diagram for the installation of capacitors.
Terminal block (X1) power supply:
switch cabinet
Terminal Block (X2) control supply (SRP 3040E):
Control voltage for all models is 220Vac.
1C
and
Do not install the compressor in chemically insalubrious areas.
Always check if the transformer's capacity can stand the compressor's power. If a
separate transformer is not available, check whether the energy supply and main
circuit breakers can stand a voltage load increase.
supplies compressor according to nominal voltage indicated in the start
3A
). Chemical gases may pass through the air inlet filter and
for price and availability). The maximum recommended working
for assistance and recommendations).
A
control supply must be apart from power supply.
39