Maintenance Parts - Schulz SRP 3040E Manual De Instrucciones

Compresor a tornillo electronico/analogico
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

SCREW AIR COMPRESSOR
PREVENTIVE MAINTENANCE
(9) The useful life of the separating element is at least 3,000 hours of work, provided that all the requirements
below are satisfied:
- installation conditions according to items 1 and 2 of the Installation chapter page 39;
- preventive maintenance executed correctly (according to the relevant chapter);
- machine operation system (load/relief cycle) not frequent.
The deadline for replacing the separating element should always be evaluated by the Technical Assistance
which attends to your screw compressor, (recommendations also valid for factory supply of both mineral and
synthetic oil).
(10) Operational conditions such as, ambient temperature, air/oil radiator obstruction for contamination, air
renewal of the house of machine, cleanness of air, oil and separator element filters, can promote discharge
temperature of the compressor unit in levels that modify the useful life of the oil.
When the discharge temperature of the compressor unit be over 194°F (90 C), the period of oil change must
attend what follows:
- If Mineral Oil – every 500 hours;
- If Synthetic Oil – every 4,000 hours.
9. UPDATING OF MAINTENANCE DATA IN THE ELECTRONIC INTERFACE
After each replacement of the lubricoolant, oil filter element and air/oil separator element, the number of
hours in the Electronic Interface must be updated. Please consult your electronic interface supplement for
instructions.
9.1. THE FIRST ELEMENT OIL FILTER CHANGE
IMPORTANT

MAINTENANCE PARTS

In order to maintain your warranty and maximize serviceability, your Schulz compressor needs routine
maintenance (as outlined in the Preventive Maintenance chapter).
The following table shows the parts and code of the maintenance materials that should be purchased from your
SCHULZ Authorized - Technical/Distributor.
Code
-
007.0136-0/AT
007.0144-0/AT
021.0009-1
021.0098-0/AT
007.0154-0/AT
021.0118-0
007.0168-0/AT
007.0169-0/AT
TABLE 5
56
The first element oil filter change must be carried out with 300 operating
hours with subsequent changes every 1,000 hours (on the Electronic units,
this interval is indicated on the display).
Denomination
Lubricant mineral oil
Air filter
Oil filter
Air/oil separator element
Belt stretcher
Heavy duty filter
Heavy duty filter kit
Heavy duty element filter primary
Heavy duty element filter secondary
SRP 3040E - SRP 3040