ISTRUZIONI ORIGINALI
Examples:
Command: START
Source: PC
Destination: Controller
02
80
30 30 30 31
STX ADDR WINDOW
Source: Controller
Destination: PC
02
80
06
03
STX ADDR ACK ETX
Command: STOP
Source: PC
Destination: Controller
02
80
30 30 30 31
STX ADDR WINDOW
Source: Controller
Destination: PC
02
80
06
03
STX ADDR ACK ETX
Command: SOFT-START (ON)
Source: PC
Destination: Controller
02
80
31 30 30 31 31
STX ADDR
WINDOW
Source: Controller
Destination: PC
02
80
06
03
STX ADDR ACK ETX
Command: SOFT-START (OFF)
Source: PC
Destination: Controller
02
80
31 30 30 31
STX ADDR WINDOW
31
03
42
WR ON ETX
CRC
38
35
CRC
30
03
42
WR OFF ETX
CRC
38
35
CRC
03
42
WR ON ETX
CRC
38
35
CRC
30
03
42
WR OFF ETX
CRC
Source: Controller
Destination: PC
02
80
STX ADDR ACK ETX
33
Command: READ PUMP STATUS
Source: PC
Destination: Controller (with address = 3)
02
83
32 30
STX ADDR WINDOW
Source: Controller (with address = 3 in stop status)
Destination: PC
02
83
32 30 35 30 30 30 30 30 30 03
STX ADDR WINDOW DATA (STATUS) ETX
32
Command: READ SERIAL TYPE
Source: PC
Destination: Controller (with address = 3 in 485
mode)
02
83
35 30 34
STX ADDR WINDOW
Source: Controller
Destination: PC
02
83
35 30 34 30
32
STX ADDR WINDOW RD DATA ETX CRC
33
101/105
TECHNICAL INFORMATION
06
03
38
35
CRC
35
30
03
RD ETX
30
03
RD ETX
31
03 42 30
87-901-005-01(A)
38
37
CRC
38
37
CRC
38
31
CRC