Never drive through automatic car washes when the roof air condition-
er is mounted.
Please ask your vehicle manufacturer if a technical inspection is re-
quired after fitting an air conditioner and whether the height entered in
your vehicule documents needs to be altered (increased height
199 mm).
If faults occur in the system's refrigerant circuit, the system must be
checked by a specialist company and properly repaired. The refriger-
ant must never be released into the air.
2.2
Handling electrical cables
Use cable ducts to lay cables through walls with sharp edges.
Do not lay loose or bent cables next to electrically conductive materi-
als (metal).
Do not pull on the cables.
Attach and lay the cables in such a manner that they cannot be tripped
over or damaged.
Always use sockets which are grounded and secured by FS switches.
The electrical power supply may only be connected by a qualified
electrician (e.g. VDE 0100, Part 721 in Germany).
Fit a fuse of at least 10 amps to the connection with the vehicle's pow-
er supply.
3
Target group
The instructions in this manual are intended for qualified personnel at
workshops who are familiar with the guidelines and safety precautions to
be applied.