DAB E.sybox Instrucciones Para La Instalación Y El Mantenimiento página 113

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 560
version of the Slave
• It is necessary to have associated the devices with each other
• If several e.sybox units have to be updated the procedure must be
repeated each time
Procedure
1. 1.
Associate the devices (see par. 7.5.5). A pop-up will appear on
the display of both e.sybox units saying::
Association between different
firmware version
Press + to update
Where in place of x.y the firmware version of the e.sybox will appear.
2. Press the [+] key on both machines.
3. Wait for the update to be successfully completed and for both ma-
chines to restart.
Problem solving
If the update has not been successful, the machine that you were trying
to update (Salve) goes into an inconsistent status which does not allow
a new automatic update. In this case the updating procedure must be
performed manually.
11.2.1.3 - Semiautomatic updating
Requirements
• It is carried out between 2 e.sybox units at a time
• The e.sybox used as the Master must have a firmware version of
4.00 or more
• The e.sybox used as the Slave must have a firmware version of less
than 4.00
• It is necessary to have associated the devices with each other
• If several e.sybox units have to be updated the procedure must be
repeated each time
Procedure
V x.y
1. Associate the devices.
The e.sybox with the older firmware (Slave) will show the screen:
The e.sybox with firmware version of 4.00 or more will show the screen:
Association between different
firmware version
Press + to update
Where in place of x.y the firmware version of the e.sybox will appear.
2. Press the [+] key on the Master machine (the one with firmware ver-
sion of 4.00 or more)
3. Switch off the electric power supply to the Slave e.sybox and wait for
the display to switch off
4. On the Slave e.sybox, supply power by holding down simultaneously
the [MODE] and [-] keys until the update screen appears.
5. Wait for the update to be successfully completed and for both ma-
chines to restart.
Problem solving
If the update has not been successful, the machine that you were trying
to update (Slave) goes into an inconsistent status which does not allow a
new semiautomatic update. In this case the updating procedure must be
performed manually.
11.2.2. - Updating the e.sybox by e.sylink
An e.sybox can also be updated by e.sylink. For the procedure, refer to
the e.sylink manual.
ENGLISH
Wait
V x.y
GB
113
Tabla de contenido
loading

Tabla de contenido