The cover kit includes:
N° 1 Heat moulded cover
N° 1 Gasket clamping plate
N° 1 Gasket
N° 1 Gasket clamp
N° 1 Intake hole covering plate
The terminal kit includes:
N° 1 Gasket
N° 1 Exhaust flange Ø 80
N° 1 Bend 90° Ø 80
N° 1 Exhaust pipe Ø 80
N° 1 Wall sealing plate
Diaphragm installation. For correct functioning
of the boiler it is necessary to install a diaphragm
on the outlet of the sealed chamber and before the
intake and exhaust pipe (Fig. 1-14). The choice
of suitable diaphragm takes place on the basis
of the type of pipe and its maximum extension:
this calculation can be carried out using the
following tables:
N.B.: the diaphragms are supplied together with
the boiler.
Fig. 1-11
Fig. 1-13
DIAPHRAGM
Fig. 1-14
Pipe extensions in metres
Diaphragm
Ø 60/100 horizontal
Ø 40
From 0 to 0.5
Ø 41.5
From 0.5 to 1.5
WITHOUT
Exceeding 1.5
Pipe extension in metres
Diaphragm
Ø 60/100 vertical
Ø 40
From 0 to 2.2
Ø 41.5
From 2.2 to 3.2
WITHOUT
Exceeding 3.2
*Extension in meters
Diaphragm
horizontal pipe Ø 80 with
two bends
Ø 40
From 0 to 17
Ø 41.5
From 17 to 24
WITHOUT
Exceeding 24
*Extension in meters
Diaphragm
vertical pipe Ø 80 with
two bends
Ø 40
From 0 to 22
Ø 41.5
From 22 to 29
WITHOUT
Exceeding 29
Pipe extensions in metres
Diaphragm
Ø 80/125 horizontal
Ø 40
From 0 to 0.5
Ø 41.5
From 0.5 to 3.3
WITHOUT
Exceeding 3.3
Pipe extension in metres
Diaphragm
Ø 80/125 vertical
Ø 40
From 0 o 5.4
Ø 41.5
From 5.4 to 8.1
WITHOUT
Exceeding 8.1
Fig. 1-12