Cal Spas Aqua SQ63 Manual Del Usaurio página 15

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

LF
Persistent low flow problems. (Displays
on the fifth occurrence of the "HFL"
message within 24 hours.) Heater is
shut down, but other spa functions
continue to run normally.
dr
Inadequate water detected in heater.
dry
Inadequate water detected in heater.
(Displays on third occurrence of "dr"
message.) Spa is shut down.
Pr
When your spa is first actuated, it will
go into Priming mode.
--For C
Temperature unknown
- - - - - -
Temperature not current in Economy or
Sleep mode.
BUF
Internal problem detected.
Stby
Standby Mode has been activated by
pressing a button combination on the
user panel.
SF
Safety Suction.
2007 Portable Spa Owner's Manual
LTR20071001, Rev. B
Follow action required for "HFL" message. Heating
capacity of the spa will not reset automatically; you may
press any button to reset.
Check water level in spa. Refill if necessary. If the water
level is okay, make sure the pumps have been primed.
Press any button to reset.
Follow action required for "dr" message. Spa will not
automatically reset; you may press any button to reset.
The Priming mode will last for up to four minutes and
then the spa will begin to heat and maintain the water
temperature in the Standard mode.
After the pump has been running for two minutes, the
temperature will be displayed.
In Economy or Sleep mode, the pump may be off for
hours outside a filter. If you wish to see the current spa
temperature, either switch to Standard mode or turn
Jets1 on for at least two minutes.
Repair required. Contact your dealer or service
organization.
Press any button to leave Standby Mode and return to
normal operation.
Spa is shut down. The display will show "SF" when a
vacuum switch closes. All functions will turn off and the
system will be disabled until a panel button is pressed.
Operating Your Spa
Page 13
Tabla de contenido
loading

Tabla de contenido