be deactivated from the panel; however, the high speed
may be started.
Option (Optional Blower)
Press the OPTION button to turn the optional
equipment on and off. If left on, the equipment will
automatically turn off after 15 minutes.
Light
Press the LIGHT button to turn the spa light on and off.
Invert
Press the INVERT button to change the numbers in the
display to read upside down. Another press returns the
display to the right-side-up position. This enables you
to read the display while you are in the spa.
Locking the Panel
To lock the panel:
Press TIME, JETS 1, and the UP button within three
seconds. When locked, the panel will display "LOCK".
All buttons are frozen except the TIME button.
To unlock the panel:
Press TIME, JETS ,1 then the DOWN button within
three seconds.
Setting the Temperature Lock
To activate the temperature lock:
Press the UP or DOWN button, TIME, JETS 1, then the
UP button within three seconds. The panel will display
"TEMP LOCK" when the set temperature is locked.
To unlock the set temperature:
Press the UP or DOWN button, TIME, JETS 1, then the
DOWN button..
Circulation Pump (optional)
If your system is equipped with a circulation pump, it
may be configured to work in one of two different ways:
1.
The circulation pump operates continuously (24
hours) with the exception of turning off for 30
minutes at a time when the water temperature
reaches 1.7˚C above the set temperature (most
likely to happen in very hot climates).
2.
The circulation pump will come on when the system
is checking temperature, during filter cycles, during
freeze conditions, or when another pump is on.
2007 Portable Spa Owner's Manual
LTR20071001, Rev. B
Preset Filter Cycles
There are two filter cycles per day. The start and end
times of each cycle are programmable. To program, set
the time as instructed above, then press MODE/PROG
to advance to the next setting (or to exit after the last
setting). The default filter cycles are as follows:
The first filter cycle is automatically activated at
8:00 AM and operates the pump until 10:00 AM.
The "FILTER 1" indicator icon will light when filter 1
is running.
The second filter cycle is automatically activated
at 8:00 PM and operates the pump until 10:00 PM.
The "FILTER 2" indicator icon will light when filter 2
is running.
The pump and the ozone generator will run during
filtration. At the start of each filter cycle, the blower will
run on highest speed for 30 seconds to clean out the
air channels. The lowest speed of pump 2 and pump 3
will run for five minutes. In the event of power loss or
shut down, the time of day will need to be reset for filter
cycles to run according to your desired programming.
Clean-up Cycle
When the pump or blower is turned on by a button
press, a clean-up cycle begins 30 minutes after the
pump or blower is turned off or times out. The pump
and the ozone generator will run for one hour.
Ozone (optional)
On most systems, the ozone generator (if installed)
runs during filter cycles (except when pump 1 is
operating at high speed on a non-circulation system)
and during clean-up cycles. On some systems, the
ozone generator operates whenever the pump runs.
If your system is configured with the optional ozone
disable feature, the ozone generator will turn off for
one hour any time a function button (JETS 1, JETS 2,
OPTION etc.) is pressed.
Freeze Protection
If the temperature sensors detect a drop to 6.7˚C
within the heater, the pump automatically activates
to provide freeze protection. The equipment stays on
until four minutes after the sensors detect that the spa
temperature has risen to 7.2˚C or higher. In colder
climates, an optional additional freeze sensor may
be added to protect against freeze conditions that
may not be sensed by the standard sensors. Auxiliary
freeze sensor protection acts similarly except with the
temperature thresholds determined by the switch and
without a four minute delay in turnoff.