BH FITNESS G-245 Instrucciones De Montaje Y Utilización página 92

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
position.
5. After wetting the electrodes, do not
slide the transmitter around on your
body as this has the effect of drying
the electrodes.
It
is
recommend
transmitter against bare skin to ensure
successful opera-tion. If a transmitter
is worn over a shirt, the shirt has to be
well wetted under the electrode area
to ensure proper conductivity.
Wear the band as high as possible
just below the breast bone with the
transmitter in the centre and the
electrode contacts flat against the
skin. Doing this correctly assures a
correct reading of the heart beat.
HOW TO IMPROVE
CONDUCTIVITY.-
The technology used for the chest
transmitters is based on measuring
ECG signals operation, it is important
for successful heart rate measurement
that a proper electrical connection
between the skin and the electrodes of
Polar Transmitter can be established
and
maintained
Sometimes, dry skin or hairy chest
can create a non-conductive layer
between the electro-desand chest
which prevents proper and reliable
operation of transmitter.
Conductivity can be easily improved
through properly wetting properly the
electrodes by water, saliva, contact
lens solution or other saline solution.
HOW TO GET A PROPER
ECG SIGNAL FOR
TRANSMITTER.-
It is possible, however, that despite
the
above
recommendation, the transmitter does
to
wear
the
during
exercise.
mentioned
not work well due to a slightly
divergent ECG signal. ECG signal of
some human beings can be so weak
or the optimum location may vary that
transmitter has to be moved slightly to
left or right in order to get sufficient
voltage difference for the proper
operation of transmitter. Weak ECG
signal can result from heart diseases,
hear
t
characteristic of heart and the location
of the body potential vectors.
Important. Do not bend or stretch the
electrode
permanently damage sensitive internal
electronic components.
Recommendation. If you have a
sunken chest, the rubber electrodes
may not make a good contact without
additional pressure and the result will
be intermittent readings. Adding a
second chest band on the transmitter
can solve this problem.
Please
remember
pulsometre, just as all devices that do
not use cables, can it be af fected by
electromagnetic interference. These
can cause incorrect readings on your
pulsometre.
Sources of interference or situations
that can cause Incorrect readings are:
- Your monitor picks up signals in a
radius
of
centimetres. If you are carrying out
exercises too near to another person
that is wearing a pulsometre, your
screen can pick up their signal. To
avoid
maintain
distance.
- Television set, computers, cellular
telephones, lines of high tension and
electric
motors
Interference.
If you observe an erratic reading move
away from the interference source.
53
surgeries
or
strips
as
this
that
approximately
the
appropriate
can
pr
natural
may
this
75
oduce