Ash or soot out of the
stove.
The Radiocontrol receives
interfernce from another
radiocontrol of a same
appliance.
Every intervention has be done from qualify staff !
Disconnect the equipment from electrical system before every maintenance operation
Every repairs must be done by our authorized assistance centre.
ALARM SIGNAL ON RADIOCONTROL DISPLAY
Alarm
Explication
In the starting
phase the
lighting of fuel
No lighting
failed or fire
has not been
noticed
Fume expeller
Fan
motor is
Lightin
breakdown
− The fire door is open
during combustion.
− No seal between the
combustion fan and
exhaus gas.
It is possible to set up the radiocontrol in order that it reconizes only that kind
of appliance.
Disconnet all available appliances, take out the batteries from the
radiocontrols, insert the batteries in the first radiocontrol you want to
program, press and keep pressed buttons 1 and 2 until "SELECT UNIT"
appears, pressing the button 2 select a number (among 0 and 3), read and
carry out the following instructions:
Connect the appliance you want to pair with the radiocontrol, wait a second
and then press on button 3, if the operation has come to a good end, on the
display appears "UNIT x LOADED".
Repeat the same operation for all other radiocontrol/appliance you intend to
program.
Keep attention that the not concerned appliances and radiocontrols for the
programmation are cleared and without batteries.
−
It is possible to program max. 4 radiocontrols, only.
Probable cause
No pellets feed
Lighting element broken
Fume feeler has not noticed
fire
Difficulties to light the
pellets
Someting is blocking the
fume motor
Electrical connections
interrupted
Breakdown motor
63/128
IT-GB-FR-ES mod. 505
− Please to close the fire door when the
stove is lighting.
− To seal every parts of exhaus system
and call the assistance centre.
− Ignition harness could ne checked
only with apparatus not electrical
connected.
− Reparation has to be done by a
qualify staff.
Cure
Check if there is pellet into the
container
Check operating of screw feeder
Check electrical wiring.
Replace lighting element.
Verify the position, operating and
electrical connection of fume
temperature feeler.
Utilize better quality of pellets
Check fume exhaust duct.
Check electrical connection of the
motor and revolotion counter
(encoder).