MENU 10 ( correct pellets)
Sometime, changing type of pellet, there are so many types of wood pellet on the market, the
combustion of the appliance can be affected. A clear signal of an inefficient combustion is
given by the quantity of pellets into the burner basket during the normal working phase: too
much or too scarce. It is possible to make some small regulations on the combution of the
appliance. Under the assumption that during the working phase the burner basket should be
full of pellet from ¼ to half of its capacity, whenever necessary, you can make some
adjustments following the below procedures:
a-
Observe the appliance and verify if the pellet is piling up till to the complete filling
of the basket or if the basket is emptying itself almost till to the extinction of the
fire.
b-
Push P3 to enter MENU.
c-
Scroll the Menu employing P5 and P6 just to arrive to MENU 10
d-
Push again P3 to enter MENU 10.
e-
A PASSWORD is required, employing P1 or P2 run on the number in the upper
part of the screen until you arrive to number 33.
f-
Push again on button P3 to confirm the Access Key and to enter into the modality of
combustion modification
g-
Use buttons P1 and P2 to modify the number shown on the display on the upper
part, as indicated in the below table; to increase the quantity of pellet you must
increase the value, to decrease the quantity of pellet, decrease the value.
ATTENTION! We recommend to modify the value increasing/decreasing by only
one number per time. Verify the working of the appliance for one or two days, after
having cleaned the burner basket, only after this period of verification eventually
make a new regulation.
h-
Terminate the regulation of the carburetion pressing shortly on button P4.
Increase the pellets
9
8
7
6
5
MENU 11 (technical info) ONLY FOR STAFF .
DETAILS OF MENU
Menu 01 FAN REGULATION - (Canalization system functions ).
Radiocontrol Display
VENT - 2
VENT - 3
The Ventilation2 will function automatically and the Ventilation3 (if the equipment is
supplied with this function) ) will remain off.
Menu 02 SET CLOCK - (Internal clock setting).
ATTENTION to program HOUR and DATE because it will influence all the ON/OFF
automatic programs.
Radiocontrol Display
DAY
CLOCK HOURS
CLOCK MINUTES
CLOCK DAY
CLOCK MONTH
4
3
2
1
Description
Ventilation2
Ventilation3
Description
day of week
hour of current time
minutes of current time
day of current date
month of current date
56/128
Low the pellets
0
-1
-2
-3
-4
IT-GB-FR-ES mod. 505
-5
-6
-7
-8
-9
Example
A
0
Example
TUESDAY
15
15
(
:38)
38
38
(15:
)
10
10
(
/05/2016)
05
05
(10/