INSTALLATION

SECTION DEDICATED TO THE INSTALLER

Rules, regulations and prescriptions

Read this manual carefully as it contains important indications and instructions
concerning the installation, use, maintenance and safety of the product.
This appliance must only be installed and used in a room deemed suitable by the specific
authorities and in compliance with the relevant rules and regulations.
The technological systems and the installation of the appliance must be done by
professional qualified personnel authorised to release the certificate of conformity and
compliance with the regulation in force.
All the laws, rules and regulations in force concerning civil and industrial buildings must
be respected, always using PPE and other means foreseen by law.
All laws, rules and regulations concerning the systems, chimney flues, electricity, water,
ventilation and aspiration must be respected.
The manufacturer declines all responsibility arising from incorrect installation,
tampering, incorrect use of the appliance, improper use, poor maintenance, and
failure to respect regulations in force.

Preliminary operations

Carefully remove the packing.
The packing material must be recycled by disposing in the special containers or in the
local municipal waste disposal site.
Before installation, make sure that the appliance is intact, in case of doubt, do not use it
and contact the vendor.

Appliance positioning

The place where the appliance is installed must have:
− A floor suitable for supporting a weight greater than that of the appliance. If the existing
building is not suitable, appropriate measures must be taken (e.g. a load distribution plate
distribution).
− Flooring suitable for heat dispersion which protects the building against fire risks.
− The installation of the appliance must guarantee easy access for its cleaning, the cleaning of
the exhaust gas ducts and the chimney flue.
− A minimum distance from adjacent inflammable material (see Safety Distances)
− A permanently ventilated room according to the regulations in force.
− Do not install the equipment into bedrooms, bathrooms or where another heating
appliance without an independent air supply (such as chimney, stove, etc.) is installed.
− Do not place the appliance in places with explosive atmosphere.

FLOOR PROTECTION

The appliance must rest on a refractory surface. In the case of inflammable flooring
(wood, carpet, etc.) prearrange a refractory base (steel sheet, tiles or similar) with the
following size:
Frontal protrusion ≥ 500 mm;
Side protrusion ≥ 300 mm;
Rear protrusion ≥ 100 mm