SAFETY DISTANCES

From NOT inflammable objects:
A > 500 mm B > 100 mm C > 50 mm D > 1000 mm
From inflammable objects and from reinforced concrete bearing walls:
A > 1000 mm B > 200 mm C > 100 mm D > 1000 mm
Any inflammable objects placed above the appliance must be kept at a safe distance of at
least 1 meter.

Connections

Before connecting the appliance, make sure that the technical characteristics indicated on
the data plate (see copy on the last page) correspond to the ones required in the order
upon purchasing.
All biomass heating appliances, in this case wood and pellet stoves, according to laws
must be provided with a chimney flue, built in compliance with regulations in force, for
the evacuation of exhaust fumes.
The points described below are rules of good construction and installation. They refer to
regulations in force (at the time this manual was printed) but are not exhaustive in
matters of systems and installation.
Always take measurements from the
outside surface of the appliance
37/128
IT-GB-FR-ES mod. 505