Changing The Filter - Abicor Binzel FES-200 Instructivo De Servicio

Ocultar thumbs Ver también para FES-200:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5 Functional description

5.2 Changing the filter

• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment consists of protective clothing, safety goggles, respirator mask
• Nobody without personal protective equipment may stay near the dust collecting drawer when filling
NOTICE
• A filter change must be carried out if, after multiple dedusting, a vacuum of >180 mbar is still reached,
 Fig. 2 Functional Description on page EN-12
1 Loosen the fixation (1) and lift off the cover.
2 Remove the hose used for monitoring the manometer pressure (on the manometer).
3 Unscrew the two lock nuts (5) on the threaded bars of the corresponding filter.
4 Remove the fastener (4).
5 Remove the filter (3).
The filter is mounted in reverse order.
EN - 14
CAUTION
class P3, protective gloves and safety shoes.
the separated dust into it.
and no other error or reason can be detected.
FES-200
Tabla de contenido
loading

Tabla de contenido