MD SERIES DIESEL FUEL PUMP
6. LIFTING AND HANDING
When carrying out lifting and handling operations, the operator must wear at least the
minimum personal protective equipment required for the work to be carried out (safety
shoes, gloves and hard hat).
Machines weighing more than 25 kg must be moved using suitable handling systems, the
capacity of which is greater than the weight of the machine to be handled. (See the weight
indicated on the packaging). If slings are needed to move the machine, they must be in
good condition and their capacity must be adequate for the weight of the machine to be
handled. (See Fig. 7).
Electric pumps weighting <25 kg can be lifted manually by the operator without having to
use lifting equipment.
7. STORAGE
The equipment must always be kept in a covered area that is not excessively damp,
protected from atmospheric agents and at a temperature of between -10°C and +40°C.
Avoid direct exposure to sunlight. If the machine is to be stored for long periods, it is
recommended not to remove it from its packaging.
8. INSTALLATION
The machines must be installed in well-ventilated, non-dusty areas and protected from the
weather. The area must be properly lit (according to the current regulations for the place
of installation), with an ambient temperature of between 5 and 40°C. Remember that the
ambient temperature and the altitude of the place of installation can affect the cooling of
the electric motor.
During installation, it is recommended to assess the place of installation carefully and
take into account the space required for carrying out maintenance on the pump unit or
the electric motor. For safety reasons, the electric pumps must be fixed, in the place
of installation, using the holes on the feet / support base. Avoid installing the motor
underneath the pump unit.
www.proindecsa.com / [email protected]