2.2 USING THE TOOL MANAGER SOFTWARE
2.2.13 HISTORY LOG ITEM LIST
Angle (After Snug)
[Display overview]
This shows the result value of the angle after snug of the work concerned.
The angle after snug is an anvil turning angle from the snug point set by the snug point
parameter to the end of work.
Number of Pulse
[Display overview]
This shows the number of pulses that the tool emitted at the work concerned.
Fastening Time
[Display overview]
This shows the time it took from trigger-on to the end of work at the work concerned.
Battery Level
[Display overview]
This shows the remaining battery level when the work concerned started in the four
levels: 3 to 0. The remaining battery level that each display shows is as follows.
3: Fully charged to adequate remaining battery level, 2: 40% or less, 1: 20% or less,
0: Dead battery.
Offset Slope
[Display overview]
This shows the configured parameter of the coefficient for converting the output voltage
of the torque sensor into torque.
Offset Intercept
[Display overview]
This shows the configured parameter of the coefficient for converting the output voltage
of the torque sensor into torque.
Snug Point Detection Method
[Display overview]
This shows the configured parameter of the [Snug Point Detection Method].
Snug Point Detection Threshold
[Display overview]
This shows the configured parameter of the threshold for determining the snug point.
The [Snug Point Detection Threshold] is displayed when the configured parameter of
the [Snug Point] is [Snug Torque] or [Select From Graph].
- 82 -
EN