2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
6
Reconnect the USB cable to connect the tool to the Tool
Manager software.
7
Select [Acquire] (④) to import the torque value measured by the
tool.
The imported value is shown in the [Tool Torque Result] column (⑤) in the upper
display window.
8
Enter the [Audit Torque Value] (⑥) checked with the torque
tester or the torque wrench.
9
Select [Check] (⑦) to calculate new offset values.
(At this point, the newly calculated offset values have not been registered in the tool yet.)
10
Check by % (⑨) the difference between the [Tool Torque Result]
(⑤) measured by the tool and the [Audit Torque Value] (⑧) in the
upper display window.
11
If the above difference is small enough, select [Update & Exit]
(⑩) to end the offset setting.
If the above difference is still large, select [Continue Offset] (⑪) to set the new offset
values to the tool and repeat steps
(When % goes into the range of 95.0% to 105.0%, values of %, offset (slope), and
offset (intercept) will turn green. Use them for reference.)
EN
4
11
to
until the difference becomes small enough.