Panasonic AccuPulse 4.0 EYFNH1XC Manual De Instrucciones página 66

Inalambrica llave de impulso mecanica electronica
Idiomas disponibles

Idiomas disponibles

2.2 USING THE TOOL MANAGER SOFTWARE
2.2.9 PARAMETER LIST
Rundown Error Detection
[Functional overview]
If the tool shuts off before the set time has passed since work started, this will be judged
NOK.
[Default value]
*0.0 s
[Setting value]
*0.0 s to 3.0 s
Retightening Prevention
[Functional overview]
Unless the selected time has passed since work was complete, the tool will not operate
even if the trigger is on.
[Default value]
*0.0 s
[Setting value]
*0.0 s to 3.0 s
Cross Thread Reduction
[Functional overview]
This is a tool operation option for reducing cross threading.
OFF:
Soft Start Up Shift Timing: The no-load speed is fixed at
360 degree Reverse:
[Default value]
OFF (Soft Start Up Shift Timing *0.0 s)
[Setting value]
OFF, Soft Start Up Shift Timing (*0.0 to 1.0 s), 360 degree Reverse
Entering the value with (*) will disable the function.
EN
Cross threading reduction function disabled.
the set time has passed since work started.
the tool lowest rpm: about 210 rpm
In order to follow a thread, the tool operates 360 degrees
reversely before operating forward.
- 66 -
the tool lowest rpm before