2.2 USING THE TOOL MANAGER SOFTWARE
2.2.8 CONFIGURING PARAMETERS OF THE TOOL
• The graph window shows a graph of the most recent history log.
The graph used for the setting can be changed from the pull-down above (①).
• By selecting [Acquire] (②), you can also import a new graph used for the setting.
• The setting window has a main window (③) that displays the entire graph and a sub
window (④) that enlarges and displays any part of the graph.
• The display range of the main window can be changed by entering the display start and
end angles in the [X-axis Range] (⑤) under the graph.
• The display range and scale of the sub window can be changed freely by moving or
resizing the selection frame (⑥) on the main window.
③
●
②
●
• The snug point is set by selecting a line between any dots on the graph from the sub
window. At the line between the selected dots, the amount of increase in torque with
respect to the tightening angle advancing by 1° is the threshold for determining the snug
point (Detection Threshold).
EN
①
●
Enlarged
⑤
●
Select
④
●
- 54 -
Continued to the next page
⑥
●
⑥
●
The selection frame can
be moved or resized
by a drag-and-drop
operation.