4.3 ERROR CODES
4.3.2 ERROR MESSAGES OF HISTORY LOGS
Category
Stop before
8 Error
shut off
Shut off
9 Error
incomplete
10 Error
Overcurrent
11 Error
Low voltage
Motor high
12 Error
temperature
Battery high
13 Error
temperature
Battery sensor
14 Error
error
EN
Error message
• Work ended before shut-off.
ー The user turned off the
trigger.
ー The stop was made by
another error.
• Work ended by both
"stop before shut-off" and
"occurrence of pulsing."
ー Stop before shut-off
ー Work was started.
• Protection stopped because
abnormal current was
observed in the tool.
ー Dependence on the work
environment
ー Dependence on the battery
or the tool
• Protection stopped because
abnormal voltage was
observed around the battery.
ー Dependence on the work
environment
ー Dependence on the battery
or the tool
• Protection stopped because
the motor of the tool is hot.
• Protection stopped because
the battery pack became hot.
• Abnormality was observed
around the battery pack
connectors to the tool.
Cause
- 103 -
Continued to the next page
Action
(for unintended cause)
<If a manual stop was made>
• Reconsider the work
environment.
• Check the member conditions.
<If another error appears>
• Check the error description and
take action.
• Refer to the section of a stop
before shut-off.
• Reconsider the work procedure.
• Reconsider the work
environment (whether there
is an abnormal load, and how
workers use the tool).
• Reconsider the battery pack
(charging or replacing with a
new one).
• Clean the connectors (check
for dust and wear in the
connectors).
• Wait for it to cool down before
use (no condensation).
< If there are continuous
abnormal loads>
• Reconsider the work
environment.
• Check the member conditions.
• Wait for it to cool down before
use.
< If there are continuous
abnormal loads>
• Reconsider the work
environment.
• Check the member conditions.
• Reattach the battery pack.
• Reconsider the battery pack
(charging or replacing with a
new one).
• Clean the connectors (check
for dust and wear in the
connectors).
loading