13 Troubleshooting
Problem
The fan rotates with difficulty or not at
all.
The fan cannot be used to heat the air.
There is no water in the pipes.
Fan speed fault.
Room temperature fault.
14 Warranty
Refer to the sections below for information about warranty and warranty support in the US, Canada, and all other re-
gions.
United States and Canada
LIMITED WARRANTY AVAILABLE ATDOMETIC.COM/WARRANTY.
IF YOU HAVE QUESTIONS, OR TO OBTAIN A COPY OF THE LIMITED WARRANTY FREE OF CHARGE, CONTACT:
Possible cause
The fan is blocked.
The fan is defective.
There are air inclusions in the fan coils.
The 3-way water valve is defective.
There are air inclusions in the water cir-
culation.
The wrong ventilation, temperature,
and/or mode settings has been made.
The temperature controller is not set
correctly.
Suggested remedy
Remove any blockages.
1.
Disconnect the power supplie
from the fan coil.
2.
Do not touch the fan coil within
the next 2 h.
3.
Contact an authorized service
agent.
1.
Ensure that the hydrometer is op-
erating at a minimum pressure of
10 mT when the ventilation sys-
tem is switched off.
2.
If the hydrometer indicates a
pressure of 0 mT or close to
0 mT, switch off the ventilation
system.
3.
Refill the ventilation system with
water to a pressure of 15 mT.
4.
Vent the ventilation system using
the vent valve on the evaporator.
5.
If the circulation of the treated
water works properly, ensure that
the blower is working correctly.
6.
Ensure that the temperature con-
troller is set correctly.
Replace the 3-way water valve
actuator or the housing.
Use the manual vent valves to
remove the air from the copper
pipes.
Select the desired setting using
the temperature controller.
Set the desired temperature us-
ing the temperature controller.
    EN