 The electrical outlet must be protected by a 16A safety cut-out switch, separately from
other electricity consumers,
 The connection between the device and the electrical network may employ a 3 meter
long (max.) extension cable with a cross-section of 1.5 mm². The use of multiple plugs
or gangs is prohibited because of the danger of fire that is involved with this.
 Make sure that the power cable is undamaged and has not been installed under the
oven or over hot or sharp surfaces.
 This appliance must be electrically grounded. In case of a short circuit grounding will
protect against electric shocks because the electrical current is diverted through the
grounding lead. The appliance is fitted with an appropriate cable with a ground lead
and a grounded safety plug. The plug must be inserted into a properly installed and
grounded outlet.
 The electrical safety of the device is only guaranteed if the device is connected to a
properly installed protective conductor system. Operations using an electrical outlet
without a protective conductor are prohibited. If in doubt, have the house installation
checked over by a qualified electrician. The manufacturer cannot be made responsible
for damages that are caused by a missing or damaged protective conductor.
15.6.1 Extension cables
 The power cable is kept intentionally short to reduce the risk of tangling or presenting a
tripping hazard.
 If a longer cable or an extension cable is required:
 1) The power rating of the cable or extension cable must be no less than the rating of
the appliance.
 2) The extension cable must a three-lead (grounded) cable.
 3) Arrange the long cable so that it does not hang down from table or counter tops
where it can be pulled by children and that it does not present a tripping hazard.