Laghetto PLAYA Serie Manual De Uso Y Mantenimiento página 51

Idiomas disponibles
  • ES

Idiomas disponibles

PLAYA - USE AND MAINTENANCE
ACTIONS TAKEN
DISPLAYED
FROM THE
MESSAGE
CONTROL SYSTEM
a LED flashes
no alarm, but
in the lower
the pool warms
right on the
slightly
display
no alarm, but
the customer
perceives a
--
shock when
entering the
pool
no alarm, but
the customer
perceives a
shock when
--
entering the
pool, even if
the heater is
off
complete
E01
blocking of all
functions
complete
E02
blocking of all
functions
ITEM THAT
POSSIBLE
GENERATED THE
ALARM
the protection
fuse output of
the heater is
interrupted,
--
the protection
tab of the
heater is
broken
heater in
dispersion
with the wrong
connection in
the terminal
--
of the control
unit (inverted
phase with
the neutral),
grounding not
adequate
grounding not
--
adequate
water
temperature
too high
water
possible
temperature >
failure of the
42 °C
temperature
sensor
possible heater
failure
faulty
malfunctioning of
temperature
the temperature
probe
probe
RECOVERY MODE
CAUSES
replace fuse,
check heater
protection tab,
replace heater
fix as from the
manual the correct
supply phase and
neutral, replace
heater, verification
of grounding by a
technician
verification of
grounding by a
technician
wait for the water
temperature to
drop.
Check the
functioning of the
temperature probe
or replace it.
The alarm resets
itself automatically
when the mini-pool
is in automatic
mode.
replace
temperature probe
51
loading

Este manual también es adecuado para:

Playa 1Playa 2Playa 3Playa twin