PARAMETER
inhibition time of the
U4
piezoelectric blower
button
inhibition time of the
U5
piezoelectric light
button
ANTI STAGNATION FUNCTION (AUTOMATIC)
It is an automatic function that activates the blower for 30 seconds and the filter
pump for 3 hours when the latter has been off for more than 48 hours.
MINIMUM TEMPERATURE FUNCTION (AUTOMATIC)
It allows you to prevent the water from cooling to ambient temperature, thus
minimizing the energy consumption and the time to bring the temperature of use.
It is automatically activated when the "water heating" function is turned off. It is
to regulate the temperature with the same function mode "Heating water using the
reference temperature = 10 °C". For the hysteresis, use the fixed value of 1 ° C.
The following table summarizes all the signal codes of alarms, with their
descriptions, that the control unit is capable of signaling.
ACTIONS TAKEN
DISPLAYED
MESSAGE
CONTROL SYSTEM
no alarm, but
the controller's
--
display does
not turn on
DESCRIPTION
it sets the time in
which the blower
button is inhibited;
only after this time it
can be pressed again
Iit sets the time in
which the is inhibited
after finishing the
cycle set in U2
parameter; only after
this time can be
pressed again
ALARM SIGNALS
ITEM THAT
FROM THE
GENERATED THE
ALARM
--
FUNCTION
POSSIBLE
CAUSES
lack of power.
Fuse of the
controller
interrupted
DEFAULT
00
sec
00
sec
RECOVERY MODE
Reset: Switch off
the power for 30
sec. and re-power
the control unit.
Check the power
supply line. Check
the fuse of the
control unit