SICK WTM10L Instrucciones De Uso página 53

Barreras fotoeléctricas híbridas
Ocultar thumbs Ver también para WTM10L:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
9382969/2024-02-23 | SICK
Subject to change without notice
Minimum distance in mm (y) between the set sensing
range and white background (90 % remission)
y
30
(1.18)
20
(0.79)
6%/6%
6%/90%
10
6%/6%
(0.39)
6%/90%
1
0
0
50
150
(1.97)
(5.91)
Recommended sensing range for
the best performance
Figure 12: Characteristic curve, WTM10L-xxxxx2
1
25
220
2
25
3
25
0
50
150
250
(1.97)
(5.91)
(9.84)
C/D
A
Recommended sensing range for
the best performance
Figure 13: WTM10L-xxxxx2
Black object, 6% remission factor, Mode 1: Speed
1
Black object, 6% remission factor, Mode 2: Standard
2
Black object, 6% remission factor, Mode 3: Precision
3
A
Sensing range min. in mm
B
Sensing range max. in mm
C
Field of view
D
Adjustable switching threshold for background suppression
Blue
Recommended sensing range for the best performance
Check the function as described in
behave as described in
see table 4, page
WTM10 with functional principle FGS
The photoelectric proximity sensor requires a background as a reference. The remission
factor and position of the background should remain as uniform as possible. The
maximum distance (x) between the photoelectric proximity sensor and background as
well as the minimum object height (y) must be upheld. As a rule, the FGS mode is used
to detect very flat objects on a conveyor belt.
Example:
Safe suppression of the background
6%/6%
6%/90%
3 3
2
Black object (6 % remission)
Set sensing range x = 300 mm
Needed minimum distance to white
x
background y = 10 mm
250
350
450
(9.84)
(13.78)
(17.72)
Distance in mm (inch)
300
400
350
450
(13.78)
(17.72)
Distance in mm (inch)
B
see table 4, page
49. If the digital output fails to
49, check the application conditions.
O P E R A T I N G I N S T R U C T I O N S | WTM10L
OPERATING INSTRUCTIONS
White background (90 %)
x
y
en
53
loading

Este manual también es adecuado para: