Bosch Climate 2000 Manual De Instalación página 27

Ocultar thumbs Ver también para Climate 2000:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
defined protection zone around the unit. The protection zone must not
overlap with public areas or adjacent sites.
Ignition sources, such as contactors, lamps or electrical switches, are
not permitted inside the protection zone.
Protection zone with floor-standing outdoor unit against a wall
1000
1000
Fig. 7
Protection zone, floor-standing outdoor unit against a wall -
dimensions in mm
1000
Fig. 8
Protection zone for installation on the floor, on the site or roof -
dimensions in mm
F
Front
Climate 2000 – 6721852025 (2024/01)
1000
0010044490-001
F
0010044491-001
Protection zone with floor-standing outdoor unit in one corner
Fig. 9
Protection zone, floor-standing outdoor unit in one corner -
dimensions in mm
2.7
Information on refrigerant
This device contains fluorinated greenhouse gases as refrigerant. The
device is hermetically sealed. You will find the information on the
refrigerant according to the Regulation (EU) No 517/2014 on
fluorinated greenhouse gases in the operating instructions of the device.
Information for the installer: If you refill refrigerant, enter the additional
charge size and the total charge size of the refrigerant in the table
"information on refrigerant" of the operating instructions.
3
Installation
3.1
Before installation
CAUTION
Risk of injury from sharp edges!
▶ Wear protective gloves during installation.
CAUTION
Danger of burns!
During operation the pipes become hot.
▶ Make sure, that the pipes cooled down before touching them.
▶ Check the scope of delivery for damage.
▶ Check whether a hissing sound due to negative pressure can be
detected when opening the pipes of the indoor unit.
3.2
Requirements for installation site
▶ Observe minimum clearances ( Figs. 53 to 54).
Indoor unit
▶ Do not install the indoor unit in a room in which open ignition sources
(for example: open flames, an operating wall mounted gas boiler or
an operating electric heating system) are in operation.
▶ The installation site must not be higher than 2000 m above sea level.
▶ Keep the air inlet and air outlet clear of any obstacles to allow the air
to circulate freely. Otherwise bad performance and higher noise level
may occur.
▶ Keep TV, radio and and similar appliances at least 1 m away from the
unit and the remote control.
▶ Mount the indoor unit on a wall that absorbs vibrations.
Installation
1000
0010044492-001
27
loading

Este manual también es adecuado para:

Cl2000u w 26 eCl2000u w 35 eCl2000u w 53 eCl2000u w 70 eCl2000 26 eCl2000 35 e ... Mostrar todo