HYDRAULIC CLUTCH BLEEDING
Proceed as follows:
- remove screws (1), cap (2) and rubber pump diaphragm;
- remove the bleeding nipple (3);
- mount a syringe in the bleeding nipple hole, then refill with
fresh fluid see LUBRICATION TABLE on page 12.
CAUTION *: NEVER use brake fluid.
- refill until fluid is discharged from the lower hole (B) on the
pump body WITHOUT BUBBLES.
40
The fluid level MUST NEVER BE below 4 mm from the top (A)
of the clutch pump body (see picture). Reassemble the re-
moved parts.