5. Electrical work
■
Manual vane angle (Wired remote controller)
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Comfort
Manual vane angle
3D i-See sensor
Setting display: SELECT
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
M-NET address
1
Identify unit Check button
Input display: SELECT
Address
Check
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
M-NET address
Vane
4-way
/2-way
Input display:Angle button
Cur.
Cursor
Angle
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Select: SELECT
Outlet
Angle
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
Setting
Note:
Do not set the draft reduction in an environment with high humidity.
Otherwise, condensation may form and drip.
1 Select "Comfort" from the Operation
menu, and press the [SELECT/HOLD]
button.
2 Select "Manual vane angle" with the [F1]
or [F2] button, and press the [SELECT/
HOLD] button.
3 Select the "M-NET address" for the
units to whose vanes are to be fi xed,
with the [F2] or [F3] button, and press
the [SELECT/HOLD] button.
Press the [F4] button to confi rm the unit.
The vane of only the target indoor unit
is pointing downward.
4 Select "Vane" with the [F1] button.
Select "4-way" or "2-way" with the [F2]
or [F3] button, and press the [F4] button.
5 The current vane setting will appear.
Select the desired outlets from 1 through
4 with the [F1] or [F2] button.
• Outlet: "1", "2", "3", "4" and "1, 2, 3, 4, (all
outlets)"
Press the [F3] or [F4] button to go
through the option in the order of "No
setting (reset)", "Step 1", "Step 2",
"Step 3", "Step 4", "Step 5" and "Draft
reduction*".
Select the desired setting.
* Draft reduction
The airfl ow direction for this setting is
more horizontal than the airfl ow direction
for the "Step 1" setting in order to reduce
a drafty feeling. The draft reduction can
be set for only 1 vane.
■
Vane setting
No setting
Step 1
Step 3
Step 4
Draft
All outlets
reduction*
Press the [SELECT/HOLD] button to save the settings.
A screen will appear that indicates the setting information is being
transmitted.
The setting changes will be made to the selected outlet.
The screen will automatically return to the one shown above (step 5)
when the transmission is completed.
Make the settings for other outlets, following the same procedures.
If all outlets are selected,
will be displayed the next time the unit
goes into operation.
Navigating through the screens
• .To return to the previous screen ....................[RETURN] button
■
Confi rmation procedure
Manual vane angle
M-NET address
1
Identify unit Check button
Input display:
SELECT
Address
Check
F1
F2
F3
F4
Manual vane angle
M-NET address
Function setting for unit
with vane fully open.
Return:
RETURN
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Manual vane angle
No communication
Check Unit state.
Return:
RETURN
F1
F2
F3
F4
Caution:
To prevent falls, maintain a stable footing when operating the unit.
Step 2
Step 5
1 Select the "M-NET address" for the units
to whose vanes are to be fi xed, with the
[F2] or [F3] button. Press the [F4] button
to confi rm the unit.
2 After pressing the [F4] button, wait
approximately 15 seconds, and then
check the current state of the air
conditioner.
→ The vane is pointing downward. →
This air conditioner is displayed on the
remote controller.
→ All outlets are closed. → Press the
[RETURN] button and continue the
operation from the beginning.
→ The messages shown to the left are
displayed. → The target device does not
exist at this refrigerant address.
• Press the [RETURN] button to return to
the initial screen.
3 Change the "M-NET address" to the
next number.
• Refer to step 1 to change the "M-NET
address" and continue with the confi rma-
tion.
11