9.2.3.
PULSES REQUIRED
This parameter defines the minimum number of pulses that the programmer must receive to
increase the balance. When the programmer receives this number of pulses the balance will be
increased with the time corresponding to the number of pulses received, considering the time
value entered in the PULSE TIME parameter. The factory value is 1. Therefore unless this value
is changed, the programmer will increase the balance with each pulse received.
PULSES REQUIRED, combined with PULSE TIME, is used to enter a minimum operating price.
For example, in the case of an appliance which operates in Euros, where 50 cents is equivalent
to one pulse, and you wish to enter a price of 3 Euros for a drying time of 40 minutes. You know
that 3 Euros are 6 pulses, therefore the minimum number of pulses should be 6 and the pulse
time should be 40/6 = 6.666 minutes = 400 seconds. PULSE TIME 400 and PULSES REQUIRED
6 should be entered. Until the programmer receives the 6 pulses, the balance will not be
increased. Once the 6 pulses have been received, the balance will be increased by 400 x 6
seconds equivalent to 40 minutes.
9.2.4.
TEMP LOW
This parameter defines the value in ºC which will be effective when the user selects low
temperature. The factory value is 40 ºC, although this can be edited.
9.2.5.
TEMP MID
This parameter defines the value in ºC which will be effective when the user selects Mid
temperature. The factory value is 50 ºC, although this can be edited.
PULSE TIME
300
PULSES REQUIRED
01
TEMP LOW-
040 ºC
TEMP MID-
050 ºC
84