5. ALARMS AND WARNINGS
The open door and open filter alarms lead to the pausing of the current programme. When the
conditions triggering the alarm disappear, the drying cycle can be restarted as soon as the alarm
is closed. The other alarms stop the programme and a warning alarm is heard. This warning is
stopped by pressing SELECT or by removing the reason for the alarm.
The following table lists the alarms and their possible causes.
Alarm
Meaning
AL-1
Door open
AL-2
Filter drawer open
AL-5
Fan motor overload
AL-6
Overheating
AL-7
Dirty filter
AL-9
Probe alarm
AL-10
Heat pump system.
Err B01
Err B02
Err B04
AL-11
Phase relay
If any of the previous alarms were to persist, consult your Technical Assistance Service. Always
use the machine's serial number for your queries.
Possible solutions
* Close the door.
* Close the drawer.
* Fan motor problem. Contact your Technical Assistance
Service.
* Check condition and clean filters.
* Clean the filter.
* Clean filter more regularly, do not reach this point.
* Problem with temperature and/or humidity sensors. Contact
your Technical Assistance Service.
* Problem with coolant circuit. Contact your Technical
Assistance Service.
* Problem in electricity supply. Phases do not follow
established order: L1-L2-L3. Contact your Technical
Assistance Service.
74