BFT THALIA BT A80 Instrucciones De Instalación página 50

Cuadro de mandos
Ocultar thumbs Ver también para THALIA BT A80:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Logic
prot. lev
protection level
(Identifies how board
SERIAL
ODE
is configured in a BFT
network connection).
ADDRESS
PUSH go
Configuration of
EXPI1 input on
input-output expan-
1 EXPI
Configuration of
on input-output
2 EXPI
expansion board.
Configuration of
EXPO1 output
on input-output
1 EXPO
expansion board
50 -
THALIA BT A80
INSTALLATION MANUAL
Cross out
Definition
Default
setting
used
0
1
Setting the
0
2
3
4
Serial mode
0
0
1
Address
0
[ ___ ]
Push&Go
0
(Only for
0
1
E5 BT A12)
0
1
2
3
4
5
6
7
8
9
10
11
1
sion board.
12
1-2
13
14
15
16
17
18
0
1
2
3
4
5
EXPI2 input
6
0
7
8
1-3
9
10
11
12
0
1
11
2
3
4-5
4
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new tran-
smitters by repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to
the receiver's memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic
setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops
radio interference, if any.
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other
boards.
Identifies board address from 0 to 119 in a local BFT network connection.
(see U-LINK OPTIONAL MODULES section)
Logic not active
Manually pushing the stopped leaf toward the opening direction determines the automatic opening.
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board
is switched automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on
input/output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on
input/output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is
switched automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while
closing the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically
to safety device test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while ope-
ning the movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically
to safety device test input, EXPFAULT1.
Input configured as Start E command.
Input configured as Start I command.
Input configured as Open command.
Input configured as Close command.
Input configured as Ped command.
Input configured as Timer command.
Input configured as Timer Pedestrian command.
Input configured as Phot (photocell) safety.
Input configured as Phot op safety (photocell active during opening only).
Input configured as Phot cl safety (photocell active during closing only).
Input configured as Bar safety (safety edge).
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing
the movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening
the movement stops.
Output configured as 2
Radio Channel.
nd
Output configured as SCA (gate open light).
Output configured as Courtesy Light command.
Output configured as Zone Light command.
Output configured as Stair Light.
Optional extras
loading