on the display
NOTE: these manoeuvres are performed in person preset mode, at slow speed,
without the intervention of the safety devices.
8.8.1) GIUNO ULTRA BT A20, GIUNO ULTRA BT A50
Using the „+/-" buttons on the display, bring the leaf in the desired position. To
adjust the limit stops, refer to the settings for limit stop adjustment provided in
the GIUNO ULTRA motor manual.
8.8.2) E5 BT A12, E5 BT A18
Using the „+/-" buttons on the display, bring the leaf in the position indicated by
the display (opening or closing). Once the desired position is reached, confirm
the position by pressing the OK button. For E5 motors, the leaf can be manually
positioned close to the limit stops by pushing the gate; then move the gate using
the „+/-" button until it is against the mechanical stopper. To confirm the position,
or use the OK button or the radio control (previously stored).
8.9) STATISTICS MENU
Used to view the version of the board, the total number of operations (in
hundreds), the number of transmitters memorized and the last 30 errors (the
first 2 digits indicate the position, the last 2 give the error code). Error 01 is the
most recent.
TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
OPEN DELAY
0
TI E
CLS DELAY
0
TI E
0
TCA
0
ped TCA
1
TRF. LGHT. C LR. T
30
t. light
output
1
ti e
0
op. dist. sloud
0
cl. dist. sloud
0
DIST. DECEL
10
ped opening
1
OP. FORCE
1
CLS. FORCE
15
OP SPEED
46 -
THALIA BT A80
INSTALLATION MANUAL
max.
Default
Personal
10
3
25
6
Motor 1 closing delay time [s]
120
10
Automatic closing time [s]
Automatic closure time from
120
0
pedestrian manoeuvre [s]
Time-to-clear traffic light
180
40
Lighting time of the courtesy
300
90
Activation time of the timed
240
10
Slow-down distance during
100
10
Slow-down distance during
100
10
100
15
Deceleration distance [%]
100
100
Leaf force during opening
100
50
100
50
Leaf force during closing [%]
100
100
8.10) PASSWORD MENU
Used to set a password for the board's wireless programming via the U-link
network.
With "PROTECTION LEVEL" logic set to 1,2,3,4, the password is required to
access the programming menus. After 10 consecutive failed attempts to log
in, you will need to wait 3 minutes before trying again. During this time,
whenever an attempt is made to log in, the display will read "BLOC". The
default password is 1234.
9) CLOSING LIMIT SWITCH PRESSURE Fig. G Ref. A-B
OPENING DIRECTION Fig. E
10) U-LINK OPTIONAL MODULES
Refer to the U-link instructions for the modules.
The use of some models causes lowered radio capacity. Adjust the system using an
appropriate antenna tuned to 433MHxz.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
Impact forces can be reduced by using deformable edges.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations).
Definition
Motor 2 opening delay
Motor 2 opening delay time with respect to motor 1.
time [s]
Motor 1 closing delay time with respect to motor 2.
NOTE: if the time is set to maximum, before starting, engine 1 waits for the
complete shut down of engine 2.
Waiting time before automatic closing.
Waiting time before automatic closure after a pedestrian manoeuvre, ONLY if
different from 0.
If the parameter is set to 0, the waiting time after a pedestrian manoeuvre is the
same as the non-pedestrian manoeuvre.
Time-to-clear for the zone run through by traffic controlled by the traffic light.
zone [s]
Lighting duration of the courtesy light [s]
light [s]
Timed radio channel output activation time in seconds
output [s]
Slow-down distance for motor(s) during opening, given as a percentage of total
travel. WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active
opening [%]
slowdown to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded;
values below 10% will be considered to be 10%.
Slow-down distance for motor(s) during closing, given as a percentage of total travel.
WARNING: Once the parameter has been edited, a complete uninterrupted
opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
ATTENTION: with actuators with integrated locks, the permanently active
closing [%]
slowdown to a value higher than 5 is mandatory.
WARNING: in GIUNO, the slow-down distance is set with the sliding sensors
ATTENTION: for the ELI BT A35 engine type, the slowing cannot be excluded;
values below 10% will be considered to be 10%.
Deceleration distance (switch from running speed to slow-down speed)
fo r m o t o r ( s ) b o t h d u r i n g o p e n i n g a n d d u r i n g c l o s i n g, g i ve n a s
a percentage of total travel. WARNING: Once the parameter has been
edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Partial opening distance as a percentage of total opening following activation of
Partial opening M1 [%]
PED pedestrian command.
Force exerted by leaf/leaves during opening. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
[%]
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-crush
safety devices where necessary (**).
Force exerted by leaf/leaves during closing. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-crush
safety devices where necessary (**).
Percentage of maximum speed that can be reached by motor(s) during opening.
WARNING: Once the parameter has been edited, a complete uninterrupted
Opening speed [%}
opening-closing cycle is required. WARNING: when the display reads "SET",
obstacle detection is not active.
Description