BFT THALIA BT A80 Instrucciones De Instalación página 42

Cuadro de mandos
Ocultar thumbs Ver también para THALIA BT A80:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 82
Diagnostics
code
START E external start input activated
STRE
START I internal start input activated
STRI
OPEN input activated
OPEN
CLOSE input activated
CLS
PED pedestrian input activated
PED
TIMER input activated
TIME
STOP input activated
STOP
Activation of PHOT photocell input or, if configured as verified photocell,
PHOT
Activation of the associated FAULT input
Activation of PHOT OP opening photocell input or, if configured as acti-
ve verified photocell only when opening, Activation of the associated
PHOP
FAULT input
Activation of PHOT CL closing photocell input or, if configured as active
verified photocell only when closing, Activation of the associated FAULT
PHCL
input
Activation of BAR safety edge input or, if configured as verified safety
BAR
edge, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE
OPENING, or, if configured as verified safety edge active only while
baro
opening, Activation of the associated FAULT input
Activation of BAR safety edge input with ACTIVE reversal ONLY WHILE
CLOSING, or, if configured as verified safety edge active only while closing,
barc
Activation of the associated FAULT input
T h e b o a r d i s s t a n d i n g b y t o p e r f o r m a c o m p l e t e
o p e n i n g - c l o s i n g c yc l e u n i n t e r r u p t e d b y i n t e r m e d i a t e
SET
stops in order to acquire the torque required for movement.
WARNING! Obstacle detection not active
Photocell test failed
ER01
Safety edge test failed
ER02
Opening photocell test failed
ER03
Closing photocell test failed
ER04
8k2 safety edge test failed
er06
Opening safety edge test failed
ER07
Closing safety edge test failed
ER08
Board hardware test error
ER1x*
Encoder error
ER2x*
Reverse due to obstacle - Amperostop
ER3x*
Thermal cutout
ER4x*
Communication error with remote devices
ER5x*
Consistency error of the control unit's parameters (Logics and Parameters)
ER72
D-track parameter error
ER73
EEPROM memory error
Er83
Internal system supervision control error.
Er8x - Er9x
Power supply overload
erF2
Error in the configuration of the logics (SAFE inputs, motor type)
ERf3
Solenoid lock output overload
ERF9
Error during limit switch adjustment
Ersw
Only for E5 BT A18 / E5 BT A12
*X= 0, 1, .., 9, A, B, C, D, E, F
42 -
THALIA BT A80
INSTALLATION MANUAL
C= SWC2 motor 2 closing limit
switch input activated
O= SWO2 motor 2 opening limit
switch input activated
C= SWC1 motor 1 closing limit
switch input activated
O= SWO1 motor 1 opening limit
switch input activated
DIAGNOSTICS
DESCRIPTION
35. 4 0
Instantaneous force motor 2
Instantaneous force motor 1
NOTES
 
 
 
 
 
 
 
 
 
 
 
 
Check photocell connection and/or logic settings
Check safety edge connection and/or logic settings
Check photocell connection and/or parameter/logic setting
Check photocell connection and/or parameter/logic setting
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
Check safety edge connection and/or parameter/logic settings
- Check connections to motor
- Hardware problems with board (contact technical assistance)
- Motor or encoder signal power cables inverted/disconnected or incorrect
programming (see Fig. E)
- Actuator movement is too slow or stopped with respect to programmed
operation.
Check fo r obstacles in path
Allow automated device to cool
Check connection with serial-connected accessory devices and/or
expansion boards
Pressing OK the detected settings are confirmed. The board will keep
on working with the detected settings.
The board settings must be checked (Parameters and Logics)
Pressing OK, the board will keep on working with D-track as a default.
An autoset is required
Check that the memory card has been inserted correctly, try turning
the card off and on again.
If the problem persists, contact technical assistance.
Try switching the board off and back on again. If the problem persists,
contact the technical assistance department.
Check that the SAFE logic or motor type configuration is correct.
-Check lock connections
- Unsuitable lock
Motor or encoder signal power cables inverted/disconnected or incor-
rect programming. (see Fig. E)
 
loading