P1012 - Multispeed Reference 2
Adjustable
0 to 18000 rpm
Range:
Properties:
-
Access Groups
SPLC
via HMI:
Description:
Sets the speed reference 2 for the Multispeed application.
P1013 - Multispeed Reference 3
Adjustable
0 to 18000 rpm
Range:
Properties:
-
Access Groups
SPLC
via HMI:
Description:
Sets the speed reference 3 for the Multispeed application.
P1014 - Multispeed Reference 4
Adjustable
0 to 18000 rpm
Range:
Properties:
-
Access Groups
SPLC
via HMI:
Description:
Sets the speed reference 4 for the Multispeed application.
P1015 - Multispeed Reference 5
Adjustable
0 to 18000 rpm
Range:
Properties:
-
Access Groups
SPLC
via HMI:
Description:
Sets the speed reference 5 for the Multispeed application.
Keypad (HMI) and Basic Programming
Factory
Setting:
Factory
Setting:
Factory
Setting:
Factory
Setting:
300 rpm
600 rpm
900 rpm
1200 rpm
CFW700 | 43