General Outline - BFT TIR 60 - 120 Instrucciones De Uso

Automatizaciones para puertas basculante y seccionales
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
ENGLISH
Thank you for buying this product, our company is sure that you will be more than satisfied with the product's performance. The product is supplied with a
"Warnings" leaflet and an "Instruction booklet". These should both be read carefully as they provide important information about safety, installation, ope-
ration and maintenance. This product complies with the recognised technical standards and safety regulations. We declare that this product is in conformity
with the following European Directives: 89/336/EEC and 73/23/EEC (and subsequent amendments).

1) GENERAL OUTLINE

Suitable for motorising sectional doors , spring overhead doors with total reentrance and overhead doors with counterweights by means of a special pulling
arm. The maximum height of the overhead door must not exceed 2.5 meters (3.5 meters with extension).
The installation is carried out easily, it allows a fast assembly without any change to the door.The closing lock is maintained by the irreversible motor reducer.
This product was designed in order to motorise the above mentioned types of doors. Any other use will be considered contrary to the use foreseen by the
manufacturer which, therefore, cannot be considered responsible for any caused damage to things, people, animals.
2) SAFETY
If correctly installed and used, this automation device satisfies the required safety level standards. However, it is advisable to observe some practical rules
in order to avoid accidental problems. Before using the automation device, carefully read the operation instructions and keep them for future reference.
Keep children, persons and things outside the automation working area, particularly during operation.
Keep radio control or other control devices out of children's reach, in order to avoid any unintentional automation activation.
Do not intentionally oppose the leaf movement.
Do not attempt to open the door manually, if the internal locking system has not been released by pulling the appropriate wire connected to the carriage,
or the external lock (SM1 or SET/S) activated.
Do not modify the automation components.
In case of malfunction, disconnect the power supply, activate the emergency release to gain access to the automation device and request the assistance
of a qualified technician (installer).
Before proceeding to any external cleaning operation, disconnect the mains powers supply.
Keep the photocell optical components and luminous signal indication devices clean. Check that the safety devices (photocells) are not obscured by
branches or shrubs.
For any direct assistance to the automation system, request the assistance of a qualified technician (installer).
Have qualified personnel check the automation system once a year.
3) EMERGENCY MANOEUVRE
In case of electric power failure or system malfunction, the manoeuvre must be carried out manually by pulling the wire connected to the carriage, as in fig.1.
For garages which are not provided with a second exit, it is compulsory to fit an external key release device like Mod. SM1 (fig.2) or Mod. SET/S (fig.3).
4 -
TIR 60-120 - Ver. 05
USER'S MANUAL
Fig. 1
Fig. 2
Fig. 3

Hide quick links:

Tabla de contenido
loading

Tabla de contenido