General Safety; Technical Details; General Information - BFT TIR 60 - 120 Instrucciones De Uso

Automatizaciones para puertas basculante y seccionales
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
ENGLISH
Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "Warnings" leaflet and an "Instruction booklet". These should both be
read carefully as they provide important information about safety, installa-
tion, operation and maintenance. This product complies with the recognised
technical standards and safety regulations. We declare that this product
is in conformity with the following European Directives: 89/336/EEC and
73/23/EEC (and subsequent amendments).

1) GENERAL SAFETY

WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this product
should be read carefully as they provide important information about
safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The construction components of this product must comply with the fol-
lowing European Directives: 89/336/CEE, 73/23/EEC and subsequent
amendments.As for all non EEC countries, the abovementioned standards
as well as the current national standards should be respected in order to
achieve a good safety level.
The Company declines all responsibility for any consequences resulting
from failure to observe GoodTechnical Practice when constructing closing
structures (door, gates etc.), as well as from any deformationwhich might
occur during use.
The installation must comply with the provisions set out by the followin-
gEuropean Directives: 89/336/CEE, 73/23/EEC and subsequent amen-
dments.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
Fit all the safety devices (photocells, electric edges etc.) which are needed
to protect the area from any danger caused by squashing, conveying and
shearing.
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components are
used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.

2) TECHNICAL DETAILS

Power supply
Motor voltage
Motor power
Absorption
Lubrication
12 -
TIR 60-120 - Ver. 05
INSTALLATION MANUAL
3,5
:230V~ +/-10%, 50/60Hz Single phase (*)
:24V=
:TIR60 - 180W / TIR120 - 260W
:TIR60 - 0.7A / TIR 120 - 0.9A
:Permanent grease
Traction and thrust
Usable stroke
Average speed (m/min)
Reaction to the collision when closing : Amperostop (Stop and reverse)
Manoeuvres in 24h
Limit switches
Courtesy light
Working temperature
Protection degree
Total weight
Dimensions
(*) Available in all network voltages.

3) GENERAL INFORMATION

Suitable for motorising sectional doors (fig. 2), spring overhead doors with
total reentrance (fig. 3) and overhead doors with counterweights by means
of a special pulling arm (fig. 4). The maximum height of the overhead door
must not exceed 2.5 meters (3.5 meters with extension).
The installation is carried out easily, it allows a fast assembly without any
change to the door. The closing lock is maintained by the irreversible motor
reducer.This product was designed in order to motorise the above mentioned
types of doors. Any other use will be considered contrary to the use foreseen
by the manufacturer which, therefore, cannot be considered responsible for
any caused damage to things, people, animals.
4) INSTALLATION OF THE AUTOMATION
Preliminary controls
Check the balance of the door.
Check the sliding of the door for all its travel.
If the door is not of new installation, check the wear state of all its component
parts. Fix or replace the faulty or worn parts.
The reliability and safety of the automation is directly influenced by the
condition of the structure of the door.
5) ASSEMBLY
Once removed the packing, the door opener presents itself as in fig. 5. We
would like to remind you to dispose of all the components of the packing
separating the different types of material (cardboard, polystyrene, PVC etc.)
according to what foreseen by the national regulations in force.
-
Remove the existing locking bolt from the door cremone bolt.
-
Place the joint "G" as in fig. 6.
-
Place the half track as in fig. 7 and lower it to the face putting the chain
mm.
into tension and obtaining in this way the whole track.
-
Place the joint divided into two between the two semi-tracks as in fig. 8.
-
Block the joint by tightening the special supplied screws as in fig. 9. The
door opener is therefore ready for the installation.
-
Mark the centre line of the door and fix the pin joint of the track to the
door frame as in fig. 10. If the height of the ceiling of the room allows
it, it is possible to assemble the pin joint higher fixing it to the masonry
headsill with wedges.
-
With the aid of a support as a ladder, lift the motorised head until levelling
the track as in fig. 11.
-
Fasten the two supporting brackets to the ceiling as in fig. 12. Check
everything again and fasten the two supporting brackets onto the base
plate of the motor reducer.
-
Unlock the pulling carriage (fig. 13) by pulling the cord and bringing the
pulling arm to the door frame. Fix the pulling arm to the door frame as in
fig.14 using the supplied screws.
6) ELECTRIC SYSTEM PREPARATION (fig.15)
I)
Type approved omnipolar switch with
provided with overload and short-circuit protection, used to break the
automation connection from the mains. If not present, provide the auto-
mation with a type approved differential switch with adequate capacity
and a 0.03 A threshold.
Qr) Control unit with built-in receiver
M) Actuator
Ft-Fr)Pair of photocells (transmitter) (receivers)
T)
1-2-4 channel transmitter
Prepare the arrival of the connec-tions of the attachments, of the safety
and control devices to the motor unit keeping the connections to the
line voltage well separated from the connections of the attachments
in low tension. Proceed to their connection as indicated in the electric
diagram (fig. 16). Once finished, if the radio receiver board is inserted
in the control unit, the equipment is ready to work with remote control.
If a remote control is not used, the actioning is carried out by means
of a start push-button connected as indicated in the general electric
diagram (fig. 16).
:TIR60 600N
: TIR120 1200N
:2.55m (with extension Mod.PT13.5m)
:TIR-60 5 appox :TIR-120 6.5 (approx.)
:TIR60
100
: TIR120
:Electric and adjustable
:Lamp 230V~ 25W max., E14
:-15°C +60°C
:IP X0
:12 kg
:See fig. 1
3,5 mm
min. contact opening.
200