ENGLISH
Thank you for buying this product, our company is sure that you will be more than
satis ed with the product's performance. The product is supplied with a "Warn-
ing" lea et and an " Instruction booklet ". These should both be read carefully
as they provide important information about safety, installation, operation and
maintenance. This product complies with the recognised technical standards and
safety regulations. We declare that this product is in conformity with the following
European Directives: 2004/108/CE, 2006/95/CE, 98/37/EEC, 99/05/EEC (and subse-
quent amendments).
1)GENERAL OUTLINE
The BOTTICELLI system is compatible with the EElink protocol for fast installa-
tion and maintenance. It is suitable for motorising sectional doors, protruding
fully retracting spring operated overhead doors and counterweight overhead
doors provided with an appropriate towing arm. The overhead door must not be
higher than 3 metres. It is easy to install and fast to t and does not need the door
to be modi ed. The irreversible gearmotor keeps the door locked in the closing
position. The control unit is builtin. It controls the operation relays and the safety
devices (photocell, rubber skirt) before performing every manoeuvre.
This product was designed to motorise the types of door mentioned above.
Any other use is considered contrary to that intended by the manufactur-
er who,therefore,cannot be held responsible for any injuries to persons or
animals,or damage to things which might derive from misuse.
2)SAFETY
If correctly installed and used, this automation device satis es the required safety
level standards. However, it is advisable to observe some practical rules in order to
avoid accidental problems. Before using the automation device, carefully read the
operation instructions and keep them for future reference.
ticularly during operation.
avoid any unintentional automation activation.
been released by pulling the appropriate wire connected to the carriage ( g.1), or
the external lock (SM1 or SET/S g.2- g.3) activated.
4 -
BOTTICELLI VENERE D
All manuals and user guides at all-guides.com
USER'S MANUAL
release to gain access to the automation device and request the assistance of a
quali ed technician (installer).
powers supply.
clean. Check that the safety devices (photocells) are not obscured by branches
or shrubs.
quali ed technician (installer).
case where any repairs or adjustments are required, given that an installation
malfunction or an incorrectly balanced door could cause injuries.
50 mm away from the oor. Should operation show to be incorrect, request the
assistance of a quali ed technician, given that an incorrect adjustment could be
dangerous.
3) EMERGENCY MANOEUVRE
In case of electric power failure or system malfunction, the manoeuvre must be
carried out manually by pulling the wire connected to the carriage, as in g.1. For
garages which are not provided with a second exit, it is compulsory to t an exter-
nal key release device like Mod. SM1 ( g.2) or Mod. SET/S ( g.3).
WARNING: If the door is not correctly balanced, activation of the carriage manual
release could provoke an uncontrolled door movement.
-
4) BULB REPLACEMENT
To replace the courtesy light bulb, remove its transparent cover ( g.4).
WARNING: Only 24V 25W max E14 bulbs must be used.
nd out any unbalance, sign of wear or damage. Do not use the operator in the
E14 24V
25W max