Mitsubishi Electric mr.Slim PLA-A EA7 Serie Manual De Instrucciones página 11

Idiomas disponibles

Idiomas disponibles

3. Operation
Confirmation procedure (wired remote controller)
Manual vane angle
Ref. address
Unit No.
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Manual vane angle
Ref. address
Unit No.
Function setting for unit
with vane fully open.
Return:
F1
F2
F3
F4
Manual vane angle
No communication
Check Unit state.
Return:
F1
F2
F3
F4
3.6. 3D i-see Sensor setting
Note:
This function cannot be set depending on the outdoor unit to be
connected.
3.6.1 3D i-see Sensor setting
Main
Main menu
Maintenance
Initial setting
Service
Main display:
Cursor
Page
F1
F2
F3
F4
Maintenance menu
Auto descending panel
Manual vane angle
3D i-See sensor
Main menu:
Cursor
F1
F2
F3
F4
1 First, confirm by setting "Ref.
address" to 0 and "Unit No." to 1.
• Move the cursor to "Ref. address"
or "Unit No." with the [F1] button to
select.
• Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
2 Change the "Unit No." in order and
check each unit.
• Press the [F1] button to select
"Unit No.".
Press the [F2] or [F3] button to
change the "Unit No." to the unit
that you want to check, and then
press the [F4] button.
• After pressing the [F4] button, wait
approximately 15 seconds, and
then check the current state of the
air conditioner.
→ The vane is pointing downward.
→ This air conditioner is displayed
on the remote controller.
→ All outlets are closed. → Press
the [RETURN] button and continue
the operation from the beginning.
→ The messages shown to the
left are displayed. → The target
device does not exist at this refrig-
erant address.
• Press the [RETURN] button to
return to the initial screen.
3 Change the "Ref. address" to the
next number.
• Refer to step 1 to change the
"Ref. address" and continue with
the confirmation.
1 Select "Maintenance" from the
Main menu (refer to page 7), and
press the [SELECT] button.
2 Select "3D i-See sensor" with the
[F1] or [F2] button, and press the
[SELECT] button.
3D i-See sensor
Air distribution
Energy saving option
Seasonal airflow
Setting display:
Cursor
F1
F2
F3
F4
3.6.2 Air distribution
Air distribution
Ref. address
Unit No.
Identify unit Check button
Input display:
Cur.
Address
Check
F1
F2
F3
F4
Air distribution
Ref. address
All
Unit No.
Auto vane
Direct/Indirect
Direct/Indirect setting
Select:
Cur.
F1
F2
F3
F4
Direct
Cooling
horizontal → swing
Heating
keep downward
3 Select the desired menu with the
[F1] or [F2] button, and press the
[SELECT] button.
• Air distribution
Select the airflow direction control
method when the airflow direction
is set to "Auto".
• Energy saving option
Operates the energy-save mode
according to whether persons are
detected in the room by the 3D
i-see Sensor.
• Seasonal airflow
When the thermostat turns off, the
fan and the vanes operate accord-
ing to the control settings.
1 Move the cursor to "Ref. address"
or "Unit No." with the [F1] button to
select.
Select the refrigerant address and
the unit number for the units to
whose vanes are to be fixed, with
the [F2] or [F3] button, and press
the [SELECT] button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the [F4] button to confirm
the unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4] but-
ton.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the
same as during normal operation.
"Area"*: The vanes move to the
down airflow direction toward
areas with a high floor tempera-
ture during Cool mode and toward
areas with a low floor temperature
during Heat mode. Otherwise,
the vanes move to the horizontal
airflow direction.
"Direct/Indirect"*: The vanes
automatically move relative to the
areas where persons are detect-
ed.
The vanes operate as indicated in
the following table.
* In order to enable this function,
the airflow direction must be set to
"Auto".
Vane setting
Indirect
keep horizontal
downward → horizontal
en
10
loading