Bosch EasyHedgeCut 18-45 Manual Original página 16

Ocultar thumbs Ver también para EasyHedgeCut 18-45:
16 | English
Charger
– Battery with 1.5 Ah
– Battery with 2.0 Ah
– Battery with 2.5 Ah
Weight according to
EPTA‑Procedure 01:2014
Protection class
The specifications apply to a rated voltage [U] of 230 V. These specifications may vary at different voltages and in country-specific models.
Noise/Vibration Information
Noise emission values determined according to EN 60745-2-15.
Typically the A-weighted noise levels of the product are:
– Sound pressure level
– Sound power level
– Uncertainty K
Vibration total values ah (triax vector sum) and uncertainty K determined according to EN 60745-2-15
– Vibration emission value a
h
– Uncertainty K
The vibration level given in these instructions has been
measured in accordance with a standardised measuring pro-
cedure and may be used to compare power tools. It can also
be used for a preliminary estimation of exposure to vibra-
tion.
The stated vibration level applies to the main applications of
the power tool. However, if the power tool is used for differ-
ent applications, with different application tools or poorly
maintained, the vibration level may differ. This can signific-
antly increase the exposure to vibration over the total work-
ing period.
To estimate the exposure to vibration accurately, the times
when the tool is switched off or when it is running but not ac-
tually being used should also be taken into account. This can
significantly reduce the exposure to vibration over the total
working period.
Implement additional safety measures to protect the oper-
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping the hands warm,
and organising workflows correctly.
Switching on
For Your Safety
Caution: Switch garden tool off and remove battery
u
from machine before adjusting or cleaning.
The blades continue to move for a fraction of a second
u
after the hedgecutter is switched off.
Do not touch the moving blades.
u
F 016 L81 850 | (23.11.2018)
AL 1815 CV
min
63
min
84
min
105
kg
0.38
/ II
Charging the Battery
The battery is equipped with temperature monitoring that al-
lows charging only in the temperature range between 0 °C
and 45 °C. In this manner, a high battery service life is
achieved.
Note: The battery is supplied partially charged. To ensure
full battery capacity, completely charge the battery in the
battery charger before using for the first time.
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging procedure
does not damage the battery.
The Electronic Cell Protection (ECP) protects the lithium-ion
battery against deep discharging. When the battery is
empty, the machine is switched off by means of a protective
circuit: The pump stops.
Do not continue to press the On/Off switch after an auto-
matic shut-off of the machine. The battery can be dam-
aged.
Observe the notes for disposal of the battery.
Inserting/Removing the Battery (see figure B)
Note: Using unsuitable batteries can lead to malfunctions or
damage the machine.
Insert the charged battery (9). Ensure the battery is inserted
correctly.
To remove the battery (9) from the machine, press the bat-
tery unlocking button (8) and pull the battery out.
AL 1830 CV
AL 1880 CV
60
95
130
0.40
/ II
3 600 H49 H..
dB(A)
dB(A)
dB
2
m/s
2
m/s
Bosch Power Tools
36
35
62
0.60
/ II
62
82
3.0
2.5
1.5
loading